Scanning

1.After programming frequencies, simply press SCAN to begin scanning. During scanning, when you rotate the

VFO, you can select the direction (or ) you want to scan.

SCAN

C 001

 

Bank

1234567890

2.The bank indicators selected for scanning appear on the display, and the bank being currently monitored flashes. You can deselect banks from active scanning by entering their number on your keypad. The indicator for each deselected bank disappears, and the bank’s channels are not scanned.

Note: One bank must always be active. You cannot deactivate all ten banks at the same time. If you try to deselect all the banks, the first bank is automatically selected.

To restore a bank to active scanning, enter the bank’s number on your keypad.

The bank’s indicator will display again.

3.During normal scanning the scanner skips unprogrammed or locked out channels.

SCAN

CHANNELS 1 2 3 4 5 6 7 8 9 10

4.When a transmission is received, the scanner stops on that channel. When the transmission ends, scanning resumes automatically.

Another method is as follows:

1.Press HOLD/MAN.

Frequency

Frequency

Locked Out

not entered

(L/O)

 

2.While the VFO setting is in the channel mode, rotate the VFO until the desired channel is displayed.

Note: When in Hold mode, you can use the VFO to step up or down through the channels. You can also switch from stepping up/down through channels to stepping up/down through frequencies by pressing the HOLD/MAN button for 2 seconds.

Storing Frequencies During Scanning

During Scanning

1.Press HOLD/MAN.

31

Image 35
Contents Page Page Contents Edacs Scat LTR IntroductionFront View Icon Description Icon DisplayBC250D Shortcuts Press Important Notice Terminology What is Scanning?What is Searching? What is Trunk Tracking?What is Apco Project 25 Digital Communications? Feature Highlights Page Scanner.uniden.com Where to Obtain More InformationInformation on the Internet Included with Your Scanner Package Low Battery Indicator SetupInstalling the Battery Pack Charging the Battery PackListening Safely Connecting the Remote CableFlexible Antenna BeltclipTurn the Scanner On Setting the SquelchBasic Operation Understanding the Menu System Menu Description and Numeric Keypad Equivalents You can assign a variety of step sizes to the search range 5TONE Data 4BEEP Alert You can assign a variety of step sizes to the channel 8I-CALLMOTOROLA/EDACS 8ID Scan List LTR Cntrl CH only 9BANK TAG Press MENU/BACK Storing Frequencies into Channels in Menu ModeUsing ProgrammingPress Deleting a Stored FrequencyEditing a Stored Frequency Duplicate Frequency Alert Assigning a Bank Tag to a Bank Press MENU/BACK Transfer Frequencies Storing Text Tags Press HOLD/MANAssigning the Beep Alert to a Channel Beep AlertProgramming Tips Page During Scanning Press HOLD/MAN ScanningStoring Frequencies During Scanning Setting the Delay Mode for Frequency RF Attenuation FeatureChannel Lockout Lockout in Hold Mode Press HOLD/MANLockout in Scanning Mode Priority Scan Restoring a Locked-out ChannelRestoring All Locked-out Channels Priority Channel Plus Scan Changing the Priority ChannelSearching Setting a Search RangeData Skip Search Hold FeatureStarting Chain Search Storing Search Frequencies Frequency SkipC004 0000.0000 Auto StoringTone Search mode Squelch SQ Mode001 512.0000 NFM Ctcss 250.3 Bank Additional Menu Options for Searching Service Option Service SearchNWR-SAME Alert Service Search SkipProgramming Fips Code Testing the Alert SirenTo clear a stored Fips code, press 0 and E successively Digital and Trunked Systems Page Selecting or Changing Trunking System Type Programming Receiving Digital and Trunked SystemsFor instructions. is complete Programming Trunking FrequenciesProgramming ID Scan Lists Manually To enter an Edacs ID To enter a Type 2 Talk Group IDTo enter a Type 1 ID Assigning a Text Tag to a Talk Group ID Press MENU/BACK To enter a LTR IDReceiving Trunked Systems ID Scan 867.9875 NFM List ID Scan ModeTrunked Search ID Scan Hold FeatureID Monitor Mode To directly access a specific channelSCAN, RSM or Search ID Search Hold and Direct Entry ID Hold ModeID Lockout To unlock all locked out IDs in a bank once Review ID LockoutRestoring Locked-out IDs To unlock a single ID, follow these steps Press MENU/BACKReverse Key Setting the Delay Mode for Trunking ModeDeleting a Stored ID Setting Priority in Trunking ModeProgramming Scan Lists During Search Call Motorola/EDACS Moving between Scan List MemoriesYou can enter the instant shortcut Multi-TrackMulti-Track Operational Details Edacs Tracking Edacs ReceptionSearch An Edacs Trunked systemAFS Partial Entry Feature Special Edacs FeaturesPatch Tracking LTR Tracking LTR ReceptionMotorola Tracking Motorola ReceptionFleet Map Programming Selecting Preset Fleet MapProgramming a Hybrid System Programming a Fleet Map50.0 Toggling the Status Bit Control Channel Only ModePage Disconnect Tone Detect Option End Code Apco Project Reception Installing the Apco P-25 CardTurning ON/OFF the Apco P-25 Card Precautions for Installing the BCi25D CardThreshold Adjustment Range Apco P-25 Sound Quality Fine TuningPage To program your scanner PC Control ModeRemote Interface To connect Scanner to PCScanner.uniden.com PC Control Parameter Clone ModeStart Remote Mode and Change Transfer Speed To connect the Scanner to Scanner MasterClone Key Lock Additional FeaturesDimmer Enter LockChannel Step Selection Reverse ModeKey Beep Option Screen MaskFrequency and Channel Tuning with the VFO Control Receiving Mode SelectionCare and Maintenance Troubleshooting Problem Suggestion Specifications Glossary of Terms Page Page Page Appendix Preset Fleet MapsPreset Map Block Type I Programming Information User Defined Fleet MapsSize Code Restrictions Fleet Map Size CodesNWR-SAME Event Code 100 101 102 BC250D Flow Charts103 104 Uniden America Corporation One Year Limited Warranty