Owner's Manual | Model No. 875.199810 |
Owner's Manual | Model No. 875.199810 |
Air Tool Hook Up
be a flexible hose in order to isolate
movement of the compressor.
Route the initial
Slope the main lines down at least 3/4 inch per 10 feet of pipe away from air compressor; this will draw the condensate with the flow of air and away from the compressor.
This tools features a power regulator ,a_zlve
(fig. 2). Rotate regulator untiJ desired output is achieved. The settings on the regu!etor are only for reference and do not denote a
specific power output. Turn regulator to position with smaller circle being the least amount of power end largef circle being/or the most amount of power, The tool only operates at maximum power in reverse.
Before the tool is connected to the air supply, dear the air hose of accumulated dust and moisture by runn{ng air freely through the air hose for 5-10 seconds.
Air HoseS for yourAir Tools
Never carry a tool by the hose or pu[I the hose to move the tool or a compressor. Keep hoses away from hea_, oil and sharp edges. Replace any hose thai is damaged, weak or worn.
Small (home) shop hard piping:
Place the first drop as far from the compressor as the size of your shop wilt allow (50 feet is optimal, although unrealistic for a small shop). The further the drop, the more that condensation can occur, and the dher the air will be when it reaches the water separator.
In older to reduce the amount of water and contaminants that get into
Figure 2
Regulator Valve
Figure 1 Illustrates a recommended air hose hook up.
A 3/8 inch ID air hose is required up to a length of 25 feet. A 3/8 inch ID hose longer than 25 feet will cause a pressure drop and may impede performance. If more length is required, a ½ inch ID air hose is recommended. Be sure all hoses and fittings are the correct size and correctly secured before using the tool.
A piping diagram for a typical home shop is shown. Some helpful tips are:
•Always use hosesandpipesrated for
higherpressurethanyour Systemwill encounter,
Never use PVC pipes for compressed air piping systems as explosion and serious injury may result.
The connection from the compressor to the initial
the water separator, install the take- offline on the top of the main air supply line for each air drop,
A Drain line should be placed at the end of the main line for condensate drainage.
Drain valves should be placed at the end of branch lines and the drain
line, and drained daily.
•ARNINGI
Once ,_bolt Or Pastener is seated, Impacting for longer than five (5) seconds will cause excessive wear and possible damage to the Impacfing mechanism, flit takes longer than five seconds to tighten or loosen your bolt or fastener, we recommend the use of a larger size impact wrench.