Lopi Horizontal Or Vertical Vent Freestanding Stove Yankee Pellet Stove manual

Page 8

8 Installation (For Qualified Installers Only)

Clearances - Straight Installation

Through the Wall Installations

Interior Vertical

 

3”

 

 

Minimum

 

 

3” Minimum

“Tee”

 

 

 

9” Minimum

 

6” Minimum

Floor Protection

6” Minimum

 

 

 

2”

Minimum

9” Minimum

Clearances - Corner Installation

Through the Wall Vents

Interior Vertical Vents

3” Minimum

3”

Minimum

3” Minimum

2”

45°

45° Elbow

 

3” Minimum

Minimum

“Tee”

3”

Minimum

6” Minimum

6” Minimum

Floor Protection

N o t e : If interior vertical pellet vent is used, the clearance to the backwall is determined by the upward-turning elbow or "Tee". It will vary in depth depending on the brand of pellet vent used (it is approximately 5"). Before placing the heater, connect the elbow or "Tee" and measure off the 3" clearance.

Travis Industries

4050418

1 0 0 - 0 1 1 5 6

Image 8
Contents Yankee 2Introduction Introduction Important InformationTravis Industries 0 0 1 1 5Table of Contents 4Safety Precautions Mobile Home Specifications Installation Options Planning The InstallationStove Placement Before You BeginClearances Straight Installation Clearances Corner InstallationVenting the Pellet Stove Maximum Venting DistancePellet Vent Termination See the illustration below Installing the Pellet VentPellet Vent Type Mobile Home Requirements Outside Air used for combustionAlcove Installation Requirements Baffle InstallationRestrictor Adjustment Door Seal VerificationInstallation Example Direct Through-the-wall Installation Installation Example Interior Vertical Installation Installation Example Class a Chimney Retrofit Installation Example Masonry Fireplace Hearth Stove Vent Flex SectionVertical Cap Cover Plate non-combustible Storm Collar Installation Example Freestanding Masonry Chimney Storm CollarSafety Notice Operation1Location of Controls Starting the Heater for the First TimeTwo Modes of Operation 0Operatio nLoading Pellets Manual Mode To Adjust the HeatOperation2 To Start2Operation Auto ModeTo Adjust Room Temperature or Start the Stove Adjusting the Fan Speed 4Operation Maintenance2 Daily Maintenance whenever using the stoveInspect the Burn Make Sure Pellets are Not Piling UpCheck Firepot for Clinkers 6MaintenanceCleaning the Firepot Door Opening Door Frame Lock Nut8Maintenance Bi-Weekly Maintenance or every 10 bags of pelletsClean the Heat Exchange Tubes Cleaning the Optional Gold Surfaces Door and optional GrillClean the Baffles Cleaning the Baffles0Maintenance Sweep Ash Into AshpanCheck Ashpan, Dispose if necessary Maintenance3Clean the Glass 2Maintenance Yearly Maintenance or every two tonsClean the Exhaust Duct Clean the Convection BlowerClean the Vent make sure the stove and vent is cool Door Alignment 4MaintenanceDoor Seal Adjusting the Door Hinge and Latch Latch AdjustmentReplacement Parts Check for Air Leaks Around the Door, Glass, and AshpanNormal Operating Sounds Exhaust BlowerSafety Label Serial NoLimited 7 Year Warranty Years 1 & 2 Coverage Parts & Labor0Optional Equipment ThermostatUsing the Remote Thermostat Optional EquipmentRemote Thermostat Pellet Log2Index