ARCHITECTURAL AND ENGINEERING SPEC

The carbon monoxide alarm shall be a BRK Model CO5120BN and shall provide at a minimum the following features and functions:

1.An electrochemical CO sensor.

2.Powered by 120V AC, 60Hz and have a monitored 9V battery backup and a solid state piezo horn rated at 85dB at 10 ft. and shall be capable of self restoring.

3.The unit shall perform self diagnostic tests and issue a malfunction warning audibly (three chirps) if the unit malfunctions.

4.A visual LED power-on indicator to confirm unit is receiving power or to confirm unit has switched to battery backup mode.

5.The CO sensor is adjusted not to detect CO levels below 30 PPM and will not alarm when exposed to constant levels of 30 PPM for 30 days. It will alarm at the following levels: 400 PPM CO between 4 and 15 minutes, 150 PPM CO between 10 and 50 minutes and 70 PPM CO between 60 and 240 minutes.

6.A test/silence button to check all alarm functions and to silence any nuisance alarms. In addition, the unit shall have a low battery silence feature to quiet the low battery chirp for up to eight hours.

7.A “Smart Interconnect” feature allows the unit to be interconnected to BRK smoke alarms. During a smoke event, the CO5120BN horn pattern shall emit

the smoke alarm horn pattern (3 beeps, pause, 3 beeps pause). During a CO event, the interconnected CO alarms sound their normal horn pattern.

8.The unit shall be capable of operating between 40°F (4°C) and 100°F (38°C) and relative humidity between 10% and 95%.

9.The unit shall at a minimum meet the requirements of UL2034, NFPA 720 and ICC.

INSTALLATION OF ALARM

Installation of this carbon monoxide alarm must conform to all B

local electrical codes and Article 760 of the National Electrical }

678

Code (NFPA 70) and NFPA 720. Interconnected units must meet the following requirements: Total length of wire interconnecting units should be less than 1000 feet, be #18 gauge or larger and be rated at least 300V. It is recommended that all units be on the same fuse or circuit breaker. If local codes do not permit, be sure the neutral wire is common to both phases.

THE PARTS OF THIS CO ALARM

1

1.

Mounting bracket

5 4

3

1

3

2.

Mounting Slots

 

 

 

 

 

 

 

 

3.

Locking Pins

 

 

 

 

4.

Hot (Black) AC Wire

 

 

 

2

5.

Nuetral (White) AC Wire

 

 

 

2

6.

Interconnect (Orange) Wire

 

 

 

7.

Battery Drawer Latch

 

 

 

 

 

 

 

 

 

 

8.

Battery Drawer - Install

 

 

 

 

 

3

 

6

9V battery here

 

 

 

 

7

4

5

9.

Quick-Connect Plug

 

}

5 4 3 2

1

 

 

 

 

 

 

 

A

 

 

 

 

 

A. Unswitched 120VAC 60 Hz source

 

8

 

 

 

B. To additional units; Maximum = 18 total

 

 

 

 

(Maximum 12 Smoke Alarms)

 

 

 

 

 

 

 

 

 

 

9

1.

CO Alarm

5.

Junction Box

 

 

 

 

 

 

 

 

 

 

 

 

2.

Ceiling or Wall

6.

Neutral Wire (White)

 

 

 

 

 

3.

Power Connector

7.

Interconnect Wire (Orange)

 

 

 

 

4.

Wire Nut

8.

Hot Wire (Black)

 

TECHNICAL SPECS

Alarm Dimensions:

5.4” dia x 1.9”H

Weight:

6.4 oz

 

 

 

 

Operating Voltage:

120V AC 60Hz w/ 9V battery backup

 

 

 

 

Operating Current:

.09 amps (standby/alarm)

 

 

 

 

Temperature Range:

40°F (4°C) to 100°F (38°C)

 

 

 

 

Humidity Range:

10% to 95% relative humidity (RH)

 

 

 

 

Audio Alarm:

85dB at 10 feet

 

 

Test/Silence:

Electronically simulates carbon

 

 

 

monoxide condition, causing the unit to alarm

 

 

Press and hold test/silence button

 

 

 

 

Alarm Reset:

Automatic when CO clears

 

 

 

Interconnections:

Up to 18 units of First Alert or BRK Smoke, CO and

 

 

Heat Alarms. Maximum of 12 smoke alarms. See

 

 

user’s manual for details.

 

 

 

 

CO Sensor:

Electrochemical

 

 

 

 

Indicator Lights/Sounds:

 

 

 

AC Power:

Constant Green LED

 

DC Power:

Intermittent Green LED

 

Local Alarm:

Red LED flashes rapidly

 

Remote Alarm:

Red LED out.

 

Latching Alarm:

Red LED flashes every 5 seconds after local alarm stops

 

 

 

Listing:

Listed to UL2034 Standard

SHIPPING SPECS:

Individual Carton Dimensions

5.54"L x 2.10"W x 5.72"H

Weight

0.61 lbs.

Cube

0.038 ft3

UPC

0 29054 85617 3

 

 

Master Carton Dimensions

13.13"L x 5.81"W x 12.13"H

Master Pack

12

Weight

9.2 lbs.

Cube:

0.54 ft3

I2of5:

300 29054 85617 4

 

 

Pallet Information

 

Cases per Layer

25

Number of Layers:

3

Cases per Pallet:

75

Units per pallet:

900

Cube:

47.3 ft3

Weight:

758 lbs.

BATTERY DRAWER LOCK

 

Push locking pin through

 

Remove Pin

hole near battery drawer

 

on the back of the alarm.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

©2009 BRK Brands, Inc. a Jarden Corporation

Company (NYSE: JAH)

3901 Liberty Street Road Aurora, IL 60504-8122 All rights reserved

 

First Alert is a registered trademark of the First Alert Trust

brkelectronics.com

BRK is a registered trademark of BRK Brands, Inc.

 

CM2931

Image 2
Contents Alarm Technical Specs Installation of AlarmArchitectural and Engineering Spec Shipping Specs