POWER ON/OFF (1)

Pressing Power button once turns the dehumidifier "ON" and pressing it again turns the dehumidifier "OFF."

Setting (2)

By pressing this button, unit will cycle through each setting with every press. The order d settings are Humidity - Cycle Timer- Delay Start - Humidity ...

Humidity (9)

When the unit is turned on, the unit will default to Humidity mode. In this setting, Humidity allows you to manually set the desired humidity level by using the humidity arrow or key (4/5). Humidity values are changed in 5% increments ranging from 35% to 70%. Humidity is shown in window (8). When pressing v arrow key when the value is 35%, the unit will operate continuously, tn this continuous operation, Lo will be displayed in the window (8). To leave continuous operation, press the arrow up or change the setting.

Cycle Timer Setting (10)

In this setting, the unit will run for

either 3, 6, or 12 hours, then shut offfor 3, 6, or 12 hours. Cycle time can be adjusted by pushing the timer arrow up or down (4/5) repeatedly to set operating time for 3, 6, or 12 hours. The cycle timer function will continue until you change the setting or turn the unit off.

Delay Start (11)

Unit can be programmed to turn on at a desired delay time by pushing the timer arrow and key (4/5). Time can be adjusted in 1 hour increments ranging from 1 to 12 hours. Delay time will be shown in window (8) and will count down to start time in 1 hour increments.

FAN SPEED (3)

Press Fan Speed to toggle between Low and High fan speeds. Speed will be shown in FAN SPEED INDICATOR (6).

BUCKET FULL INDICATOR (7).

When the collection bucket is full, BUCKET FULL indicator (7) will come on. The dehumidifier will not run until the bucket is empty.

IMPORTANT:

When the unit is turned off and restarted, the unit will operate at the previous operation setting,

NOTICE:

A power failure will require the unit to be turned back on manually and adjusted to the desired setting.

POWER ON/OFF (1)

Pressing Power button once turns the

dehumidifier "ON" and pressing it again turns the dehumidifier "OFF."

Setting (2)

By pressing this button, unit will cycle through each setting with every press. The order of settings are Auto - Humidity - Cycle Timer- Delay Start - Auto ...

Auto (9)

When the unit is turned on, the unit will default to Auto mode. AUTO (9) and "50%" humidity value will be displayed in window (8). In this setting, humidity level is automatically set for 50% RH. Because lower temperatures usually correlate with lower humidity levels, the unit will not run frequently. At higher temperatures higher humidity is normal so the unit will run more often.

Humidity (9)

In this setting, Humidityallows you to manually set the desired humidity level by using the humidity

Varrow or key (4/5). Humidityvaluesare changed in 5% increments ranging from 35% to 70%. Humidity is shown in window (8). When pressing arrow keywhenthevalueis 35%,theunitwill operate continuously. In this continuous operation, Lo will be displayed in the window (8). To leave contin- uous operation,pressthe arrow up or changethe setting.

Cycle Timer Setting (10)

In this setting, the unit will run for either 3, 6, or 12 hours, then shut offfor 3, 6, or 12 hours. Cycle time can be adjusted by pushing the timer arrow up or down (4!5) repeatedly to set operating time for 3, 6, or 12 hours. The cycle timer function will continue until you change the setting or turn the unit off.

Delay Start (11)

Unit can be programmed to turn on at a desired delay time by pushing the timer arrow and key (4/5). Time can be adjusted in 1 hour increments ranging from 1 to 12 hours. Delay time will be shown in window (8) and will count down to start time in 1 hour increments.

FAN SPEED (3)

Press Fan Speed to toggle between Auto, Low, and High fan speeds. Speed will be shown in FAN SPEED INDICATOR (6). When AUTO is selected, the unit wilt adjust the fan speed accordingly depending on the humidity level.

BUCKET FULL INDICATOR (7)

When the collection bucket is full, BUCKET FULL indicator (7) will come on. The dehumidifier will not run until the bucket is empty.

IMPORTANT:

When the unit is tumed off and restarted, the unit will operate at the previous operation setting.

NOTICE:

A power failure will require the unit to be turned back on manually and adjusted to the desired setting.

8

9

Image 5
Contents Nmo Disclaimer of implied warranties limitation of remedies Kenmore Dehumidifier Use & Care GuideDehumidifier, these safety precautions must be followed Important Cautions for Using Your DehumidifierThis Appliance Ground ProngFused and Properly Grounded Electrical Supply is Required Choosing the Proper LocationCycle Timer Setting Power ON/OFFBucket Full Indicator FAN SpeedCleaning Front Grill and AIR Filter Cleaning the ExteriorCleaning the Bucket OPTION1.EMPTYING ManuallyModel 50351 50501 50701 Power Supply Classification SpecificationHumidity Setting Cycle Timer 12 Hours Delay TimeSU-HOGAR Your Home
Related manuals
Manual 8 pages 24.08 Kb

251.25011, 251.50701, 251.25013, 251.50351, 251.50501 specifications

Kenmore is a trusted brand known for delivering reliable and efficient appliances, and its range of vacuum cleaners is no exception. Among the models featured are the Kenmore 251.25013, 251.25011, 251.50351, 251.50701, and 251.50501. Each of these vacuum cleaners comes equipped with unique features and innovative technologies, making them suitable for various cleaning needs.

The Kenmore 251.25013 model is designed with a powerful motor that provides strong suction for deep cleaning carpets and hard floors. It features a multi-cyclonic filtration system that helps to minimize dust and allergens, ensuring a cleaner and healthier environment. Its lightweight design ensures easy maneuverability, while the telescoping wand and various attachments allow users to reach tight spaces and clean different surfaces effectively.

The 251.25011 is perfect for pet owners, featuring specialized pet hair attachments that effectively capture fur from upholstery and carpets. Its HEPA filtration system traps 99.97% of dust and allergens, making it an excellent choice for allergy sufferers. The model also includes an automatic height adjustment feature that adapts to different floor types, ensuring thorough cleaning on carpets, hardwood, and tile.

The Kenmore 251.50351 model stands out with its advanced Smart Wash technology, which automatically adjusts the cleaning mode based on the surface being cleaned. This ensures optimal cleaning performance while conserving energy. Additionally, it has an extended reach with its long power cord and hose, allowing users to clean larger areas without constantly switching outlets.

The 251.50701 model is appreciated for its ergonomically designed handle and lightweight structure, making it easy to use for extended periods. It features a spacious dustbin that is easy to empty, along with washable filters for cost-effective maintenance. Its quiet operation is especially beneficial for households with babies or pets, reducing disturbances during cleaning.

Lastly, the Kenmore 251.50501 incorporates smart technology that can be controlled via a smartphone app, allowing users to schedule cleanings or monitor performance remotely. Its intelligent mapping feature ensures comprehensive cleaning coverage in multiple rooms. The powerful suction capability and versatile attachments make it adaptable to a variety of cleaning tasks.

Overall, the Kenmore models 251.25013, 251.25011, 251.50351, 251.50701, and 251.50501 cater to diverse cleaning needs, ensuring efficiency, convenience, and high performance in everyday household tasks while incorporating the latest technologies for an enhanced user experience.