Only qualified service personnel shall perform installation and service.

NOTICE: On the horizontal / counterflow furnace wiring harness, remove the lock-ring from the end of the flexible metal conduit connector BEFORE connecting the electrical couplings.

10)On the highboy and lowboy furnace wiring harnesses, snap the strain relief fitting into the knockout opening in the burner junction box. On the horizontal / counterflow furnace wiring harness, insert the conduit fitting through the knockout opening in the burner junction box and thread on the lock-ring from the inside of the junction box. Tighten the lock-ring until it is snug.

11)Close and secure the junction box cover on the burner.

The oil burner provided with this furnace requires additional installation, set-up, and proper adjustment. Refer to the furnace instruction manual and the oil burner manufacturer’s operating instructions for detailed information on the following items.

Completion of fuel line connections to burner

Initial firing of burner

Adjusting the fuel pump pressure

Setting the draft control

Adjusting the burner combustion air