Sub-Zero BBQ242BI, Model BBQ36C, BBQ36BI, Model BBQ242C dimensions Installation N O T E S

Page 5

Planning Information

36" (914) Gas BBQ Grills

M O D E L S B B Q 2 4 2 B I / B B Q 2 4 2 C / B B Q 3 6 B I / B B Q 3 6 C

I N S T A L L A T I O N N O T E S

Refer to the illustrations and specifications for overall dimensions, finished rough opening dimensions and installation specifics.

IMPORTANT NOTE: Safe and satisfactory oper- ation of your Wolf gas BBQ grill depends upon its proper use and installation. Minimum clear- ances to combustible surfaces must be observed. Be certain the appliance is properly grounded to avoid shock hazard.

The Wolf gas BBQ grill must be specified natural or LP gas at the time of order. The gas type cannot be converted.

When choosing a portable site for your Wolf gas BBQ grill, always maintain a minimum clear- ance of 24" (610) from all four sides of the grill to any combustible surface.

When choosing a permanent built-in location for your Wolf gas BBQ grill, maintain minimum clearances to combustible surfaces as shown in the Installation illustration.

IMPORTANT NOTE: In all instances, you must allow for an adequate supply of fresh air for proper combustion and ventilation. Never locate the grill in an enclosed area.

The Wolf gas BBQ grill is designed for easy placement into a built-in enclosure. For a combustible enclosure, use the Wolf approved insulated jacket and maintain minimum clear- ances to combustible surfaces as shown in the Installation illustration on page 4.

Built-in installations require a deck to support the bottom. The supporting deck and counter should be level and strong enough to support 400 lbs (181 kg).

The Wolf gas BBQ grill requires a 110/120 V electrical supply to operate the rotisserie motor. The 6' (1.8 m) power supply cord provided with the grill is equipped with a 3-prong, grounded plug for protection against shock hazard. The service should have its own 15 amp circuit breaker.

IMPORTANT NOTE: A ground fault circuit interrupter (GFCI) is not recommended and may cause interruption of operation.

Wolf gas BBQ grills are designed to operate on natural gas at 5" (127) WC (water column) pressure or LP gas at 10" (254) WC pressure. The maximum gas supply pressure to the regulator should never exceed 14" (356) WC;

.5 psi (3.5 kPa).

Wolf recommends the use of a 1/2" (13) I.D. commercial type flex hose; this is the minimum size that may be used. All plumbing to the flex hose must be 3/4" (19) minimum I.D. pipe.

IMPORTANT NOTE: A separate external gas shut-off valve must be located near the grill in an accessible location.

The Wolf gas BBQ grill functions up to 6000' (1828 m) in altitude without any adjustment. If the installation is above 6000' (1828 m), contact your Wolf dealer.

You must follow all National Electrical Code and gas regulations. In addition, be aware of local codes and ordinances when installing your services.

Refer to the installation instructions shipped with each Wolf product for detailed specifica- tions.

Dimensions in parentheses are in

millimeters unless otherwise specified.

5

Image 5
Contents 36 914 Gas BBQ Grills E R a L L D I M E N S I O N S A T U R E SBBQ36C BBQ36C-LPBBQ36BI BBQ36BI-LP C E S S O R I E SM E N S I O N S Installation I N C O M B U S T I B L E E N C L O S U R EInstallation N O T E S