Active Time of Transfer

-Able to set the time limit for the alarm image transfer.

-In case of setting Always, image will be transferred whenever alarming.

-In case of setting Only Scheduled Time, image will be transferred only the defined date and time for the related alarm even when alarming.

Schedule Transfer Setup

-Transfer the image at the date and time automatically when the user defines.

I/O Port

E

Consists of 4 Alarm inputs and 3 Alarm outputs and functions to execute connecting Preset or Pattern to detect the Alarm input from the external Sensor, and output the Alarm output signal from the outside. If the Alarm signal input lasts over 150 ms, it will be recognized as the Alarm signal. And the Alarm operation time depends on the Preset Dwell Time to each Alarm and the Pattern connection of it.

1. ALARM PRIORITY SET

Set the priority of the 4 Alarm inputs and react the Alarm input according to the priority.

Default priority is Alarm1: 1, Alarm2: 2, Alarm3: 3, Alarm4: 4

If alarming synchronously and setting the same priority, operates by the Default priority. While alarming, Motion is not detected.

2. ALARM IN SET

Set the input Type as “NO" (Normal Open), “NC" (Normal Close), “Off" according to the connected Sensor features.

3. ALARM OUT SET

Confront to one of the 3 Alarm outputs for each Alarm inputs

3-51

3-52