Bard PA13602-C manuals
Household Appliance > Air Conditioner
When we buy new device such as Bard PA13602-C we often through away most of the documentation but the warranty.
Very often issues with Bard PA13602-C begin only after the warranty period ends and you may want to find how to repair it or just do some service work.
Even oftener it is hard to remember what does each function in Air Conditioner Bard PA13602-C is responsible for and what options to choose for expected result.
Fortunately you can find all manuals for Air Conditioner on our side using links below.
Bard PA13602-C Installation Instructions
24 pages 731.21 Kb
2 CONTENTS3 Getting Other Information and PublicationsFOr mOre InFOrmatIOn, cOntact these PublIshers: 4 General InstructIOns10 InstallatIOnlOcatIOn tYPIcal InstallatIOnsManual 2100-467K Building Air Inlet Supply and Return Ducts 11 SideView TopSupply DuctFIGure 2 slab mOuntInG at GrOunD leVel FIGure 3 aIrFlOW anD serVIce access clearances 12 * AS REqUIRED* 1120-445 TH5220D1151 15 Low Voltage WiringUnit Control Panel Thermostat Subbase 16 start uPtOPPInG OFF sYstem charGe saFetY PractIces: start uP nOtes 17 start uP anD OPeratIOnthree Phase scrOll cOmPressOr start uP InFOrmatIOn sequence OF OPeratIOn InDOOr blOWer mOtOr cOmPressOr cOntrOl mODule 18 aDJustmentslOW ambIent cOntrOl Fan blaDe settInGs serVIce anD trOubleshOOtInGserVIce hInts Pressure serVIce POrts 19 r-410areFrIGerant charGe20 Manual 2100-467K (continued on Page 20 in table 11)If incorrect charge suspected (more than +4psigsuction,+10psigliquid), TablesbaseduponratedCFM(airow)acrosstheevaporatorcoil. table 9 Pressure tablecOOlInG LOW SIDE PRESSURE +4 PSIG HIGH SIDE PRESSURE +10 PSIG 21 Manual 2100-467K table 10 Pressure tablecOOlInG If incorrect charge suspected (more than +4psigsuction,+10psigliquid), TablesbaseduponratedCFM(airow)acrosstheevaporatorcoil. LOW SIDE PRESSURE +4 PSIG HIGH SIDE PRESSURE +10 PSIG suctIOn anD DIscharGe tube brazInG 22 23 Manual 2100-467K FIGure 10 TROUBLESHOOTING GE X13-SERIES ECM2.3 trOubleshOOtInG Ge x13-serIes ecm2.3 mOtOrsIf the Motor is Running If the Motor is Not Running Manual 2100-467H Page 22 of 23 FIGURE 10 MOTORSIf the Motor is Running If the Motor is Not RunningL2 LINE POWER EARTH GROUND L1 LINE POWER NOTE: MOTOR IS CONSTANTLY POWERED BY LINE VOLTAGEManual 2100-467K Page 24 of 24 FIGure 11 FIGURE 11 24 trOubleshOOtInG Ge x13-serIes ecm2.3 mOt Ors Model X13 Communication Diagnostics MOTORS TROUBLESHOOTING GE X13-SERIES ECM2.3 Manual 2100-467H Page 23 of 23 CONTD.Model X13 Communication Diagnostics 24VAC "R" Signal through thermostat output. 24VAC Common 24VAC Common 24VAC "R" Signal through thermostat output.
Also you can find more Bard manuals or manuals for other Household Appliance.