Honeywell Y8610U manuals
Personal Care > Oxygen Equipment
When we buy new device such as Honeywell Y8610U we often through away most of the documentation but the warranty.
Very often issues with Honeywell Y8610U begin only after the warranty period ends and you may want to find how to repair it or just do some service work.
Even oftener it is hard to remember what does each function in Oxygen Equipment Honeywell Y8610U is responsible for and what options to choose for expected result.
Fortunately you can find all manuals for Oxygen Equipment on our side using links below.
Honeywell Y8610U Specifications
24 pages 1.46 Mb
PRODUCT DATA Y8610U Intermittent Pilot Retrofit KitGENERAL FEATURES 2 ORDERING INFORMATIONSPECIFICATIONS 6 PLANNING THE INSTALLATIONFrequent Cycling Water or Steam Cleaning High Humidity or Dripping Water Corrosive Chemicals Dust or Grease Accumulation Heat 7 INSTALLATIONWhen Installing this ProductMaintenance Requirements in Severe Environments Perform the Pre installation Safety Inspection 8 Shut Down ApplianceCheck Appliance Wiring Remove Standing Pilot Gas Control 9 Remove ThermocoupleInstall Igniter-Sensor Assembly 10 Install the Gas ControlConverting Between Natural and LP Gas Install Adapters to Gas Control (if used)393690-14 Straight Flange (3/4 in.) Bushings Install Gas Control Piping 11 Mount Gas ControlConnect Pilot Gas Tubing Locate and Mount the S8610U Intermittent Pilot Module 12 CAUTIONLocation Mounting Wire the SystemConnect Vent Damper (Optional) 13 Connect Ignition CableWiring ConnectionsFig. 16. Y8610U connections in a heating system with an atmospheric burner and no vent damper. 14 SETTINGSS1 DIP SWITCH DIP Switch (S1) SettingsFig. 17. DIP switch (S1) - shown with factory default settings (OFF) for SW1 and SW2. Fig. 18. DIP switch (S1) and jumper (P4) location. Table 6. DIP Switch (S1) Settings. Prepurge Trial For Ignition SW1 SW2 None 90 seconds OFF OFF ON 1 2 S1 Jumper 15 CHECKOUTStep 1: Perform Visual Inspection. Step 2: Verify Ignition Control System Ground. Step 3: Review Normal Operating Sequence and Ignition Control Module Specifications. Step 4: Reset the Ignition Control Module. Step 5: Check Safety Shutoff Operation. Step 6: Check Normal Operation. 16 OPERATIONTrial for Pilot Ignition Main Burner Operation Failed Trial for Pilot Ignition 17 TROUBLESHOOTINGTroubleshooting Sequence Ignition System Checks 19 LED Status and Troubleshooting21 Troubleshooting GuideRefer to the Fig. 22 for troubleshooting the S8610U control module.NOTE: 24 VAC CALL FOR HEAT IS ALWAYS CONNECTED TO THE TH-W TERMINAL ON THE MODULE. Fig. 22. Troubleshooting Guide. 22 ANSI STANDARDS
Also you can find more Honeywell manuals or manuals for other Personal Care.