Taylor taylor manuals
Kitchen Appliance > Refrigerator
When we buy new device such as Taylor taylor we often through away most of the documentation but the warranty.
Very often issues with Taylor taylor begin only after the warranty period ends and you may want to find how to repair it or just do some service work.
Even oftener it is hard to remember what does each function in Refrigerator Taylor taylor is responsible for and what options to choose for expected result.
Fortunately you can find all manuals for Refrigerator on our side using links below.
56 pages 2.35 Mb
3 Table of Contents5 Section 1 To the Installer8 Section 2 To the OperatorCompressor Warranty Disclaimer 9 Section 3 Safety10 SS S S7 Models 150, 152, 162, 168 Operator Parts Identification 11 Section 4 Operator Parts IdentificationModel 150Figure 1 8Models 150, 152, 162, 168Operator Parts Identificati on 12 Model 152Figure 2 9 Models 150, 152, 162, 168 Operator Parts Identification 13 Model 162Figure 3 10 Models 150, 152, 162, 168Operator Parts Identificati on 14 Model 168Figure 4 11 Models 150, 152, 162, 168 Operator Parts Identification 15 Models 150 & 152 Door AssemblyFigure 5 12 Models 150, 152, 162, 168Operator Parts Identificati on 16 Models 162 & 168 Door Assembly17 Models 150 and 152 Accessories14 Models 150, 152, 162, 168Operator Parts Identificati on 18 Models 162 and 168 Accessories19 Section 5 Important: To the Operator22 Section 6 Operating Procedures31 Section 7 Important: Operator ChecklistDuring Cleaning and Sanitizing Troubleshooting Bacterial Count Regular Maintenance Checks 32 Winter Storage33 Section 8 Troubleshooting Guide32 Models 150, 152, 162, 168Parts Replacement Schedule 36 Section 9 Parts Replacement Schedule37 Section 10 Limited Warranty on Equipment39 Section 11 Limited Warranty on Parts42 Section 12 Parts List51 150/152 050416-12 MODEL #150 CONNECT INTERNAL YELLOW TO TERMINAL 5 FOR "CW" ROTATION OF GE/RBC BEATER MOTOR FOR AND INTERNAL YELLOW TO TERMINAL 2. MODEL #152 CONNECT INTERNAL BLUE TO TERMINAL 5 3) FOR "CCW" ROTATION OF GE/RBC BEATER MOTOR FOR AND INTERNAL RED TO TERMINAL 2. MODEL #150 CONNECT INTERNAL BLACK TO TERMINAL 4 FOR "CW" ROTATION OF A.O. SMITH BEATER MOTOR FOR AND INTERNAL BLACK TO TERMINAL 2. MODEL #152 CONNECT INTERNAL RED TO TERMINAL 4 2) FOR "CCW" ROTATION OF A.O. SMITH BEATER MOTOR FOR AND INTERNAL T8 TO TERMINAL 4. MODEL #150 CONNECT INTERNAL T5 TO TERMINAL 2 FOR "CW" ROTATION OF LEESON BEATER MOTOR FOR AND INTERNAL T5 TO TERMINAL 4. MODEL #152 CONNECT INTERNAL T8 TO TERMINAL 2 1) FOR "CCW" ROTATION OF LEESON BEATER MOTOR FOR NOTES: VISCOSITY CONTROL TERMINALS: FIG. 4FIG. 2 FIG. 1 SHR COMPRESSOR WIRING TECUMSEH COMPRESSOR WIRINGL1 L2 (INTERNAL) BLK (INTERNAL) 4WHT/RED GRN/YEL A. O. SMITH BEATER MOTOR (SEE NOTE #2)WHTGE/RBC BEATER MOTOR (SEE NOTE #3) AND INTERNAL BLUE TO TERMINAL 2. FIG. 3 52 150/152 050416-274) THE EQUIPTENTIAL GROUND IS ONLY REQUIRED FOR FIG. 1 VISCOSITY CONTROL TERMINALS: AND INTERNAL BLUE TO TERMINAL 2. MODEL #150 CONNECT INTERNAL YELLOW TO TERMINAL 5 FOR "CW" ROTATION OF GE/RBC BEATER MOTOR FOR AND INTERNAL YELLOW TO TERMINAL 2. MODEL #152 CONNECT INTERNAL BLUE TO TERMINAL 5 3) FOR "CCW" ROTATION OF GE/RBC BEATER MOTOR FOR AND INTERNAL RED TO TERMINAL 2. MODEL #150 CONNECT INTERNAL BLACK TO TERMINAL 4 FOR "CW" ROTATION OF A.O. SMITH BEATER MOTOR FOR AND INTERNAL BLACK TO TERMINAL 2. MODEL #152 CONNECT INTERNAL RED TO TERMINAL 4 2) FOR "CCW" ROTATION OF A.O. SMITH BEATER MOTOR FOR AND INTERNAL T8 TO TERMINAL 4. MODEL #150 CONNECT INTERNAL T5 TO TERMINAL 2 FOR "CW" ROTATION OF LEESON BEATER MOTOR FOR AND INTERNAL T5 TO TERMINAL 4. MODEL #152 CONNECT INTERNAL T8 TO TERMINAL 2 1) FOR "CCW" ROTATION OF LEESON BEATER MOTOR FOR NOTES: FIG. 2 SHR COMPRESSOR WIRING FIG. 4A. O. SMITH .5 HP BEATER MOTOR (SEE NOTE #2) INTERNATIONAL UNITS. GE/RBC BEATER MOTOR (SEE NOTE #3) LEESON BEATER MOTOR (SEE NOTE #1) FIG. 3TECUMSEH COMPRESSOR WIRINGBLK BLK208/230 VOLTS, 60HZ (DOMESTIC) L1 L2 BRN BLU208/230 VOLTS, 60HZ (INTERNATIONAL) L1 L2 OR N EQUIPOTENTIAL GROUND (SEE FIG. 5) FIG.5 WIRE COLORS - BASED ON INCOMING POWER 53 150/152 050416-40 MODEL #150 CONNECT INTERNAL YELLOW TO TERMINAL 5 FIG. 1 FOR "CW" ROTATION OF GE/RBC BEATER MOTOR FOR AND INTERNAL YELLOW TO TERMINAL 2. MODEL #152 CONNECT INTERNAL BLUE TO TERMINAL 5 2) FOR "CCW" ROTATION OF GE/RBC BEATER MOTOR FOR AND INTERNAL T8 TO TERMINAL 4. MODEL #150 CONNECT INTERNAL T5 TO TERMINAL 2 FOR "CW" ROTATION OF LEESON BEATER MOTOR FOR AND INTERNAL T5 TO TERMINAL 4. MODEL #152 CONNECT INTERNAL T8 TO TERMINAL 2 1) FOR "CCW" ROTATION OF LEESON BEATER MOTOR FOR NOTES: VISCOSITY CONTROL TERMINALS: FIG. 4FIG. 2 SHR COMPRESSOR WIRINGGE/RBC BEATER MOTOR (SEE NOTE #2) AND INTERNAL BLUE TO TERMINAL 2. LEESON BEATER MOTOR (SEE NOTE #1) FIG. 3TECUMSEH COMPRESSOR WIRING 54 050205-12BLU/WHT "CCW" ROTATION FIG. 1 FIG. 2 FIG. 6 FIG. 3 FIG. 4GE/RBC BEATER MOTOR "CCW" ROTATION (SEE NOTE #2) MIX LOW PCB A. W/CHIME MIX LOW PCB A. W/CHIME/SNOOZE 55 050205-27REF VISCOSITY CONTROL STR REF VISCOSITY CONTROL BLACK/WHITE STRIPE VISCOSITY CONTROL 1. L1 2. N.C. CONTACT 3. N.C. CONTACT 4. L2 5. LINE 6. LOAD FIG. 1 56 050205-40sFIG. 3 FIG. 2FIG. 1 FIG. 4A. O. SMITH .5 HP BEATER MOTOR (SEE NOTE #1) FIG. 6BLK BLK GRN RED BLK RED RED MIX LOW PCB A. W/CHIME/SNOOZE FIG. 5LEFT MIX LOW SWITCH LEFT MIX LOW LIGHT MIX LOW TRANSFORMER YEL RIGHT MIX LOW SWITCH RIGHT MIX LOW LIGHT ORN BLU MODELS WITH CHIME OPTION MIX LOW PCB A. W/CHIMEGE/RBC BEATER MOTOR "CCW" ROTATION (SEE NOTE #2) LEESON BEATER MOTOR "CCW" ROTATION
Also you can find more Taylor manuals or manuals for other Kitchen Appliance.