WARNING

VENT HOOD(S) MAY BE

EXTREMELYHOT

DURING OPERATION.

FIGURE3

REFER TO FIG. 1 FOR CONNECTION DETAILS. BEFORE ATTACHING THE GAS LINE BE SURE THAT ALL GAS PIPE IS CLEAN ON THE INSIDE.

TO TRAP ANY DIRT OR FOREIGN MATERIAL IN THE GAS SUPPLY LINE, A DIRT LEG (SOMETIMES CALLED DRIP LEG) MUST BE INCORPORATED IN THE PIPING, FIG. 1. The dirt leg must be readily accessible. Install in accordance with recommendations of serving gas supplier. Refer to the latest edition of ANSI Z223.1.

To prevent damage, care must be taken not to apply too much torque when attaching gas supply pipe to thermostat gas inlet. The thermostat inlet has a pad for use with a backup wrench.

Apply joint compounds (pipe dope) sparingly and only to the male threads of pipe joints. Do not apply compound to the first two threads. Use compounds resistant to the action of liquefied petroleum gases. Do not use teflon tape on thermostat fittings.

CONNECTION OF GAS PIPE

1.When connecting gas pipe to unit, apply wrench to flange only. Note: Do not use wrench on gas valve or gas valve bracket.

2.PERFORM THE GAS LEAK TEST ANY TIME WORK IS DONE ONA GAS SYSTEM TOAVOID THE POSSIBILITY OF FIRE OR EXPLOSION WITH PROPERTY DAMAGE, PERSONAL INJURY, OR LOSS OF LIFE.

The Gas Leak Test is performed as follows: Paint pipe connections upstream of gas control with a rich soap and water solution to test for leaks before operating main burner. Bubbles indicate gas leak. To stop leak, tighten pipe connections. After piping connections are checked, turn on main burner. (See Lighting and Operating Installations in this manual or on water heater.) With main burner in operation, paint pipe joints (including flanges), pilot gas tubing connections and control inlet and outlet with rich soap and water solution. Bubbles indicate gas leak. To stop leak,

tighten flange screws, joints and pipe connections. Replace part if leak can't be stopped.

DISCONNECT THE APPLIANCE AND ITS INDIVIDUAL SHUT OFF VALVE FROM THE GAS SUPPLY PIPING SYSTEM DURING ANY SUPPLY PRESSURE TESTING EXCEEDING 1/2 PSI (3.5 kPa). GAS SUPPLY LINE MUST BE CAPPED WHEN DISCONNECTED FROM THE HEATER. FOR TEST PRESSURES AT 1/2 PSI (3.5 kPa) OR LESS, THE APPLIANCE NEED NOT BE DISCONNECTED, BUT MUST BE ISOLATED FROM THE SUPPLY PRESSURE TEST BY CLOSING THE MAIN MANUAL GAS VALVE.

BEFORE PLACING THE HEATER IN OPERATION, CHECK FOR GAS LEAKAGE. USE SOAPAND WATER SOLUTION OR OTHER MATERIAL ACCEPTABLE FOR THIS PURPOSE. DO NOT USE MATCHES CANDLES, FLAME OR OTHER SOURCES OF IGNITION TO LOCATE GAS LEAKS.

RELIEF VALVE

A NEW TEMPERATURE AND PRESSURE RELIEF VALVE COMPLYING WITH THE STANDARD FOR RELIEF VALVES AND AUTOMATIC GAS SHUT OFF DEVICES FOR HOT WATER SUPPLY SYSTEMS, ANSI Z21.22 (LATEST EDITION) MUST BE INSTALLED IN THE HEATER IN THE MARKED OPENING PROVIDED. THE VALVE MUST BE OF A SIZE (INPUT RATING) THAT WILL BE ADEQUATE FOR YOUR SIZE HEATER.

Check the metal tag on the relief valve and compare it to the heater’s rating plate. The pressure rating of relief valve must not exceed the working pressure shown on the rating plate of the heater. In addition the hourly Btu rated temperature steam discharge capacity of the relief valve shall not be less than the input rating of the heater. NO VALVE IS TO BE PLACED

6

Page 6
Image 6
A.O. Smith FPSH - 75 owner manual Connection of GAS Pipe, Relief Valve

FPSH - 75 specifications

The A.O. Smith FPSH-75 is a prominent model in the lineup of water heaters offered by A.O. Smith, a company renowned for its innovative approach to water heating solutions. This residential water heater is designed to meet the demands for both efficiency and performance, making it a popular choice for households seeking reliable hot water supply.

One of the standout features of the FPSH-75 is its impressive 75-gallon capacity, which is suitable for larger households or properties that require high volumes of hot water. This feature ensures that multiple fixtures can be used simultaneously without the worry of running out of hot water. Additionally, the unit is equipped with a powerful heating element that provides rapid heating, making it efficient for quick recovery times even during peak usage.

The FPSH-75 utilizes advanced insulation technology to minimize heat loss, which enhances energy efficiency. This means that the water heater can maintain the desired water temperature while consuming less energy. As a result, homeowners can enjoy significant savings on their energy bills, all while benefiting from consistent hot water availability.

This model is also designed with user-friendly controls, allowing homeowners to set and adjust their water temperature preferences easily. The intuitive interface ensures that users can operate the unit without hassle, optimizing their water heating experience.

Safety is also a critical consideration in the design of the FPSH-75. It comes with built-in safety features, including a temperature and pressure relief valve, which helps prevent potential hazards associated with overheating and excessive pressure buildup. Moreover, the durable construction of the tank is engineered to withstand corrosion, extending the lifespan of the water heater.

Installation is made convenient with the FPSH-75, as it is compatible with various plumbing setups, making it adaptable for a range of home designs. The model has been certified for meeting the industry standards, ensuring reliability and peace of mind for end-users.

In summary, the A.O. Smith FPSH-75 is an exceptional water heating solution, ideal for families and homes needing robust hot water delivery. Its combination of high capacity, energy efficiency, user-friendly controls, and safety features make it a top contender among residential water heaters, ensuring that homeowners can enjoy comfort and convenience without compromise.