4.Repeat Step 3 for each field that you wish to change.
5.Assign the selections by pressing Enter or Return.
6.Momentarily press RESET on the MPU front panel, or perform a soft reset, in order to re- initialize the X.25 configurations.
Reference:
Reference:
Stop! You have completed this procedure.
Table
| SET |
| CONFIGURABLE |
DATA LINK PARAMETER | VALUE | RANGE | DEFAULT |
Address Field Assignment * |
| DTE, DCE (A=1, B=3) | DTE (A=3, B=1) |
|
|
|
|
Modulo | 8 |
|
|
|
|
|
|
Window Size (K) * |
| 1 to 7 frames | 7 |
|
|
|
|
Frame Size (Bits per I frame) * |
| 1080, 2104 bits | 2104 |
|
|
|
|
N2 (retransmission count) * |
| 2 - 16 | 7 |
|
|
|
|
T1 (retry timer) * |
| 2 to 20 seconds | 3 seconds |
|
|
|
|
T2 (response delay timer) | 0.3 seconds |
|
|
|
|
|
|
T3 (not supported) |
|
|
|
|
|
|
|
T4 (not supported) |
|
|
|
|
|
|
|
* These are
Table
VIRTUAL | CIRCUIT | LOGICAL |
|
CIRCUIT | TYPE | CHANNEL # | APPLICATION |
1 | PVC | 1 | TL1 |
|
|
|
|
2 | PVC | 2 | Craft |
|
|
|
|
3 | SVC | N/A | N/A |
|
|
|
|
Note: Autonomous messages are always sent except when inhibited by the TL1