ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance

DLP-562

Page 2 of 3

8.Move to the HDSL Facility Alarms toggle fields. Select CRITICAL, MAJOR, MINOR, EVENT, or NOT RPTD for each field that you wish to change.

Reference: TAP-101Alarm Troubleshooting

9. Assign the selections by pressing Enter or Return.

Stop! You have completed this procedure.

HLX ALARM LEVELS

Group: 6

Slot: 1

Equipment Alarms

=============================================================================

COMM

FAIL

: MAJOR

HSKP1

: MINOR

PRIMARY

POWER

: MAJOR

LOOP

REVERSAL

: EVENT

HSKP2

: MINOR

SECONDARY POWER : MAJOR

TP/RNG REVERSAL

: EVENT

 

 

VERSION

MISMATCH: MAJOR

DS1 Facility Alarms

=============================================================================

AIS

: EVENT

LOF

: MAJOR

T-BERL

: MINOR

CUSTOMER LOOPBACK: MINOR

LOS

: MAJOR

YELLOW

: EVENT

NETWORK LOOPBACK : MINOR

 

 

 

 

HDSL Facility Alarms

=============================================================================

DC CONTINUITY

: MAJOR

T-BERP

FE: MINOR

T-SNR

FE

: EVENT

LOF

FE

: MAJOR

T-BERP

NE: MINOR

T-SNR

NE

: EVENT

LOF

NE

: MAJOR

T-PA

FE

: EVENT

 

 

 

RECOVERY

: MINOR

T-PA

NE

: EVENT

 

 

 

Press CONTROL-A For Assistance

6153-C

Figure 562-1. HLX Alarm Levels Screen (with Default Values)

2-197

© 2000, ADC Telecommunications, Inc.