Page 12 of 18
Table
FIELD | TYPE | OPTIONS | DESCRIPTION | DEFAULT |
|
BIT ERROR SETUP FIELDS |
|
|
|
| |
|
|
| OVERVIEW: Bit errors can be injected by the RTAU using the |
|
|
|
|
| Bit Error Set Up fields. These sections are |
|
|
|
|
| are only displayed when the line code setting is INTERNAL. The |
|
|
|
|
| Status field always shows the current status if the line code is |
|
|
|
|
| INTERNAL, but the Error Counts and Elapsed Time fields only |
|
|
|
|
| show a value when a measurement is being made. |
|
|
|
|
|
|
|
|
Error Count | Input | Range of 0 to | Select either Error Count or Error Rate for bit error setup. Both | 0 |
|
|
| 1544 | cannot be set at the same time. If single errors or a burst of |
|
|
|
|
| errors is desired, set the Error Count field to the number of |
|
|
|
|
| errors to insert. If the Error Count field is set, the number of |
|
|
|
|
| errors will be transmitted each time the Enter key is pressed. |
|
|
|
|
|
|
|
|
Error Rate | Toggle | OFF, | Select either Error Count or Error Rate for bit error setup. Both | Off |
|
|
| cannot be set at the same time. If a steady error rate is desired, |
|
| |
|
| set the Error Rate field, which indicates the rate bit or frame |
|
| |
|
|
| errors are injected. |
|
|
|
|
|
|
|
|
Error Locn | Toggle |
| OVERVIEW: The Error Location field must be set to either | N/A |
|
|
|
| PAYLOAD or FBE if the count or rate field is set. Pressing |
|
|
|
|
| the Enter or Return key will cause the RTAU to send the |
|
|
|
|
| errors. |
|
|
|
|
|
|
|
|
|
| N/A | Indicates count is 0 and rate is off. |
|
|
|
|
|
|
|
|
|
| PAYLOAD | Bit errors are injected. |
|
|
|
|
|
|
|
|
|
| FBE | Frame Bit Error. Frame errors are injected. |
|
|
|
|
|
|
|
|
Error Counts – | Display | None | Blank |
| |
Data | only |
|
|
|
|
|
|
|
|
|
|
Error Counts – | Display | None | Blank |
| |
BPV | only |
|
|
|
|
|
|
|
|
|
|
Error Counts – | Display | None | Blank |
| |
Frame | only |
|
|
|
|
|
|
|
|
|
|
Error Counts – | Display | None | Blank |
| |
CRC | only |
|
|
|
|
|
|
|
|
|
|
Error Counts – | Display | None | Blank |
| |
COFA | only |
|
|
|
|
|
|
|
|
|
|
Status – F Sync | Display | None | * or blank | Blank |
|
| only |
|
|
|
|
|
|
|
|
|
|
Status – P Sync | Display | None | * or blank | Blank |
|
| only |
|
|
|
|
|
|
|
|
|
|
Status – RAI | Display | None | * or blank | Blank |
|
| only |
|
|
|
|
|
|
|
|
|
|
|
|
|
| (continued) |