The three classes of interlock groups available are:
1.Global Interlock: Groups 1 and 2 are global and may be extended to all chassis in a system, using a
2.Horizontal Interlock: Groups 3 and 4 are horizontal and they include only modules in the individual chassis. With this grouping, all modules having a jumper placed on group 3 make up one group, and all modules with a jumper on group 4 make up the other group. These groupings do not extend out of the chassis and are not affected by the interchassis interlock cable. Each module interlock group jumper block may have no more than one jumper installed at a time.
3.Vertical Interlock: The vertical interlock jumper position is labeled V. Placing a jumper in this position interlocks all modules in the same slot location in other chassis having a jumper installed on the same V position. Interchassis interlock cables must be installed between chassis. The interchassis interlock cable is a 20 position ribbon cable
LEDs show the status of eight
Caution: The bank switching feature is not compatible with the group interlock feature. If no module in an interlocked group is in the B state when a bank switch to the B state is initiated, only the first module in this group will switch to the B state. Data may be lost when more than one module is in the B state of an interlocked group. If one module in an interlocked group is in the B state when a bank switch is initiated, the rest of the modules in that interlocked group do not switch to the B state; consequently, the system maintains its integrity.