6.3Alarm Time Delay Setting
Time delay values are fixed. The switch positions are time values ranging from none to 105.9 seconds nominal. The
Time delay settings (8 position switch) are denoted on the front panel by varying length arcs around the rotary switch, the longer the arc – the greater the time delay. Time delay settings (16 position switch) are denoted on the switch by numbers and letters. Set desired time delay before installing module in the chassis. Time delay values are listed in Table
6.4Adapter Installation
Working at the back of the chassis, install
6.5Module Installation
Carefully install PatchSwitch X.21 modules into the chassis making sure connectors on the bottom edge of the module engage the slots on the mother board as appropriate. Using a #3 Phillips head screwdriver tighten hold down screws on the front of the modules.
6.6Cable Connections
The next step is to attach the data communications network to the rear connectors.
The top two rear X.21 connectors are provided for the attachment of the DTE portion of the circuit. Bring the end of the “B” DTE cable in from one side of the equipment rack and connect it to the middle connector on the adapter. Bring the end of the “A” DTE cable in from one side of the equipment rack and connect it to the top connector on the adapter.
The bottom rear X.21 connector is provided for the attachment of the DCE portion of the circuit. Bring the end of the DCE cable in from the other side of the equipment rack and connect it to the bottom connector.
Form the cables neatly away from the modules along the back of the chassis towards the equipment rack upright. Use cable ties as necessary to secure cables in place.
Plug in the power supply or turn power on to establish power for the modules.
Page