flag ($) occurs in the AB command string, the user must issue a GO command to perform the switching operations. If an execute flag (#) occurs in the AB command string, the CM executes the AB command string immediately when it is received.
Caution: When using Autofallback, the operator’s switching commands may be negated. That is, modules in alarm state switch to the side specified by the jumper (A or B). This switching operation is performed regardless of the operator’s commands.
The The format for the AB command is:
AB , <namslot> , <numslot> , <numskip>, <action> ,<flag>
Table
Table
| COMMAND STRING |
|
OPERATION | PARAMETERS | DEFINITIONS OR COMMENTS |
Request to | AB, <namslot>, | AB — indicates a switch request. |
Switch Module | <numslot>, | namslot> — name of starting slot. Range: |
| <numskkp>,<action> | No default. |
| <flag> | numslot> — number of slots to switch. Range: |
|
| |
|
| Default = l. ALL = 0. |
|
| <numskip> — number of slots to skip between switched slots. |
|
| Range: |
|
| action> — indicates the action the switch is to perform. |
|
| Range: |
|
| Where: 0 — switch to “A” |
|
| 1 — switch to “B” |
|
| 2 — toggle switch to opposite position. |
|
| No default. |
|
| <flag> - command flag. No default. |
|
| Where: # = Execute |
|
| $ = Echo |
Examples: | AB,4,1,0,1# | Switch only slot 4 module to the “B” side. Execute command |
|
| immediately. |
| AB,0,0,0,0$ | Return command (echo) character string to originating |
|
| terminal. |
| GO | Enter GO command to execute switch request (preceding |
|
| character string). Switch all modules to the “A” side. |
| AB,0,8,1,1# | Switch 8 slots (modules) to the “B” side, starting with |
|
| module 0, skipping every other slot. Execute command |
|
| immediately. Modules 0, 2, 4, 6, 8, 10, 12, 14 and l6 switch |
| AB,5,,,0# | to the “B” side. |
| Switch only module 5 to the “A” side. Execute command | |
|
| immediately. |
|
|
|