Installation 11

Replacement of the connection cable

To replace the connection cable use only H05V2V2-F T90 or equivalent type. Make sure that the cable section is applicable to the voltage and the working temperature. The yellow/ green earth wire must be approximately 2 cm longer than the brown (or black) phase wire.

Building In

min. 600 mm

 

min. 450 mm

min. 650 mm

min. 55 mm

 

30 mm

 

480 mm

560 mm

 

 

A

10 mm

11 mm

3 mm

11 mm

A - supplied seal

A

B

A - supplied seal

B - supplied brackets

Possibilities for insertion

Kitchen unit with door

The panel installed below the hob must be easy to remove and let an easy access in case a technical assistance intervention is necessary.

 

30 mm

a

min 20 mm

(max 150 mm)

60 mm

 

b

 

a) Removable panel

Page 11
Image 11
AEG HG654320NM user manual Replacement of the connection cable, Building, Possibilities for insertion