Table 1-4a. Performance Specifications for Series 668xA1
Parameter Agilent Model Number
6680A 6681A 6682A 6683A 6684A
Output Ratings
Voltage: 0 - 5 V 0 - 8 V 0- 21 V 0 - 32 V 0 - 40 V
Current:* 0 - 875 A 0 - 580 A 0 - 240 A 0 - 160 A 0 - 128 A
*Derated linearly 1%/°C from 40 ° C to 55 °C
Programming Accuracy (@ 25 ± 5 °C)
Voltage: 0.04% + 5 mV
8 mV 21 mV
32 mV 40 mV
Current: 0 . l % + 450 mA 300 mA
125 mA
85 mA
65 mA
Ripple & Noise (from 20 Hz to 20 MHz with outputs ungrounded, or with either output terminal grounded)
Constant Voltage: rms 1.5 mV 1.5 mV 1.0 mV 1.0 mV 1.0 mV
Constant Voltage : p-p 10 mV 10 mV 10 mV 10 mV 10 mV
Constant Current:** rms
**With load inductance > 5µH. 290 mA
190 mA 40 mA 28 mA 23 mA
Readback Accuracy (from front panel or over GPIB with respect to actual output @ 25 ± 5 °C)
Voltage: 0.05% + 7.5 mV 12 mV 32 mV 48 mV 60 mV
±Current 0.1% + 600 mA 400 mA 165 mA 110 mA 90 mA
Load Regulation (change in output voltage or current for any load change within ratings)
Voltage 0.002% + 190 µV 300 µV 650 µV 1.1 mV 1.5 mV
Current: 0.005% + 65 mA 40 mA 17 mA 12 mA 9 mA
Line Regulation (change in output voltage or current for any line change within ratings)
Voltage: 0.002% + 190 µV 300 µV 650 µV 1.1 mV 1.5 mV
Current: 0.005% +
65 mA 40 mA 17 mA 12 mA 9 mA
Transient Response Time (for the output voltage to recover to within 150 mV following any step change from 100% to
50% or 50% to 100% of the rated output current): < 900 µs
AC Line Input * (selectable - see Appendix C)
Range 1
Ac input phase-to-phase voltage:
Ac input frequency:
3-phase 180-235 Vac
47-63 Hz *
Range 2
Ac input phase-to-phase voltage:
Ac input frequency:
3-phase 360-440 Vac
47-63 Hz *
* Power source can be DELTA or WYE.
* For 47 to 53 on Range 1 only, derate output voltage linearly from 100% at 200 Vac to 95% at 180 Vac.
Notes: 1For Supplemental Characteristics, see Table 1-4b.