OmniSwitch Troubleshooting Guide September 2005 page -129
debug hre pcam mode range
This command displays the range of PCAM indices assigned to each mode.
debug hre pcam mode range slot/slice
Syntax Definitions
slot Specifies an NI slot number.
slice Specifies an NI slice (ASIC) number.
Defaults
N/A
Platforms Supported
OmniSwitch 7700, 7800, 8800
Usage Guidelines
OS-66000 series does not have a HRE so this commands is not supported on these switches.
Examples
-> debug hre pcam mode range 11/0
mode 0: 00000 -> 03fff
mode 1: 04000 -> 07fff
mode 2: 08000 -> 0bfff
mode 3: 0c000 -> 0ffff
Release History
Release 5.1; command was introduced.
Related Commands
N/A