Additional Dryer Security . . .

(Metered Models)

WARNING

To reduce the risk of electric shock, fire, explosion, serious injury or death:

Disconnect electric power to the dryer before servicing.

Never start the dryer with any guards/ panels removed.

Close gas shut-off valve to gas dryer before servicing.

Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the dryer is properly grounded.

W138

Enclosed in the shipping bag are four tamper-resistant screws. When used, these screws will provide additional security for your dryer.

Located on the service door of the dryer is a flat Phillips head screw. During shipment, this screw is used to attach the service door to the meter case. For additional security, this screw can be reinstalled inside the control hood of your washer.

The following list is the procedure required to install the Phillips head screw and tamper-resistant screws:

1.Remove the Phillips head screw from service door (see illustration).

2.Remove two screws holding control panel to control hood.

3.Tilt control panel forward and lay on a protective pad to prevent scratching of cabinet top.

4.Insert phillips head screw down through double “D” hole in left rear corner of cabinet top (inside control hood) until it engages retainer nut located on left rear corner gusset of cabinet.

5.Finger tighten screw.

IMPORTANT: Do not use a power driver to tighten screw. Torque of a power driver could over-tighten screw causing damage to cabinet assembly.

6.Secure control panel to control hood using two No. 8 tamper-resistant screws, Part No. 35528.

7.While supporting lower access panel, remove two screws from bottom edge. Gently lower access panel to disengage guide lugs from bottom edge of front panel.

8.Remove two screws holding bottom tabs on front panel to dryer cabinet. Swing bottom of front panel away from dryer far enough to disengage hold-down clips and guide lugs from cabinet top.

9.Disconnect wires from door switch.

NOTE: Refer to wiring diagram when rewiring switch.

10.Remove two cabinet top hold-down scerws and install two #10 tamper-resistant screws, Part No. 62853.

11.Reinstall door switch and front panel and install two #10 tamper-resistant screws, Part No. 62853 to secure lower access panel.

NOTE: Tamper-resistant bits and bit holder, for installation of tamper-resistant screws, are available as optional equipment at extra cost.

DOUBLE “D” HOLE

#8 SCREWS

35528

#10 SCREWS

62853

#10 SCREWS

 

62853

 

 

D237IE1A

Bit (No. 8 screws) ...................

Part No. 281P4

Bit (No. 10 screws) .................

Part No. 282P4

Bit Holder (3/8 drive)..............

Part No. 24161

504523