Before Placing Tumbler into Service

1.Remove or open all panels, and check accessible bolts, nuts, screws, terminals and fittings for tightness.

2.Replace all panels and guards.

3.Turn on electrical supply to tumbler.

4.Open the supply valve for gas or steam heated tumblers.

5.After performing the previous checks, start the tumbler by pressing START. (Refer to the Operating Manual for detailed instructions.) Release the start button and open the loading door. The cylinder should stop rotating within seven seconds after the door is opened a maximum of 2 inches (51 mm). If it does not, adjust the loading door switch. Refer to Adjustments section.

6.Gas Tumblers: Start the tumbler and check the burner flame. Adjust the air inlet shutter as required. Refer to the Adjustments section.

IMPORTANT: The electronic ignition system will attempt to light the gas by sparking for the “trial for ignition” period. Refer to Table 2. If gas does not ignite within this period, the ignition control will go into a safety lockout and the valve will no longer open until the control is reset. It may be necessary to retry several times to bleed air from the gas lines. To reset, open and close the loading door and restart tumbler.

 

Prepurge

Trial for

To Reset

Location

Time

Ignition

Lockout

 

(seconds)

(seconds)

Condition:

 

 

 

 

CE and

18

10

Press reset

 

 

button on rear

Australia

 

 

 

 

of machine

 

 

 

 

 

 

 

All others

1-3

10

Open loading

 

 

door

 

 

 

 

 

 

 

 

Table 2

 

If lockout condition persists, check that the manual gas shut-off valve is in the “ON” position and that the gas service is properly connected. If condition still persists, remove tumbler from service.

7.Load the cylinder with a full load of clean rags and run to remove oil or dirt from cylinder.

8.Wipe out the cylinder using an all-purpose cleaner or detergent and water solution. Refer to Figure 5.

Installation

T452I

T452I

Figure 5

If the tumbler does not meet ANY of the listed requirements, remove tumbler from use. Refer to Removing Tumbler from Service section.

Required for CE Models Only

Once machine is installed, please be sure to complete the following items:

Review and verify machine operation with customer.

Leave all literature and a signed Declaration of Conformity with customer.

Review machine warranty information with customer.

Apply warning sticker on front panel of machine, in language appropriate to country of sale (included in literature packet).

70269701

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

25