Electrical Requirements

For 21 kW Models:

 

 

 

 

 

30 Pound Electric

 

 

 

 

 

T30 Electric not available in single phase.

 

 

 

 

 

 

 

 

 

 

 

Terminal Block

 

Recommended

 

Recommended

Serial Plate

Current

Fuse or

Breaker

Minimum

Connections

Voltage

(Amps)

Breaker Rating

Poles

Conductor Size

Required

 

 

(Amps)

 

[AWG (mm2)]

208V/60Hz/1ph

L1, L2, Neutral,

108

150

2

1/0 (53.5)

and ground

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

240V/60Hz/1ph

L1, L2, Neutral,

94

125

2

1 (42.4)

and ground

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

200V/60Hz/1ph

L1, Neutral,

108

150

1

1/0 (53.5)

and ground

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

200V/50Hz/1ph

L1, Neutral,

105

150

1

1/0 (53.5)

and ground

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

230-240V/50Hz/1ph

L1, Neutral,

95

125

1

1 (42.4)

and ground

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

200-208V/60Hz/3ph**

L1, L2, L3,

62***

80*

3

4 (21.2)

and ground

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

200V/50Hz/3ph**

L1, L2, L3,

60

80*

3

4 (21.2)

and ground

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

230-240V/50Hz/3ph**

L1, L2, L3,

55***

70*

3

4 (21.2)

and ground

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

240V/60Hz/3ph**

L1, L2, L3,

54***

70*

3

4 (21.2)

and ground

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

380V/50Hz/3ph**

L1, L2, L3,

33***

45*

3

8 (8.37)

and ground

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

380V/50Hz/3ph

L1, L2, L3,

34

45*

3

8 (8.37)

(035E Model)

and ground

 

 

 

 

 

 

 

 

 

 

400-415V/50Hz/3ph**

L1, L2, L3,

31***

40*

3

8 (8.37)

and ground

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

460-480V/60Hz/3ph**

L1, L2, L3,

27***

35*

3

8 (8.37)

and ground

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*3 Phase machines should not have fuses, breakers only.

**These serial plate voltages are only options available on the 30 Pound Single and Stacked electric models. Current (Amp) is for one pocket only.

***Per heater on T30 electric models, each has two heaters.

Table 12