Chapter 2: Installing the AT-RPS3000 Chassis and Power Supply Modules
68
5. Secure the cable to the port by tightening the two thumbscrews.
Figure 49. Securing the AT-RPS-CBL1.0 Cable to the AT-RPS3000
Chassis
6. Repeat this procedure to connect additional x610 Series switches to
the AT-RPS3000 Chassis.
B
B
1
2
3
4
SYSTEM
PoE+ / SYSTEMPoE+ / SYSTEM
SYSTEM
MODULE B
MODULE A
A
A
AT-PWR800
DC OUT
FAULT
AT-PWR800
DC OUT
FAULT
2146
100-240 VAC~12A MAX
100-240 VAC~12A MAX