SIZING INSTRUCTIONS

WELL-X-TROL®

POTABLE WATER WELL TANK

1400 Division Road, West Warwick, RI 02893 T: 401.884.6300 F: 401.885.2567 www.amtrol.com

Series 420 & 447

Pressure Switch

 

 

This handbook will discuss the basic sizing used for our larger Well-X-Trol®ssuch as WX-400, 420, 440, and 450 series. This allows you to use the Well- X-Trol®“principle of separation of air and water” on larger jobs that are beyond the typical residential range.

The Well-X-Trol®models we’ll be working with in this handbook are listed in Table 1.

The design features of these larger models allow us to apply them more creatively than the smaller residential models found in the Well-X-Trol®100, 200, and 250 series.

The Larger Well-X-Trol®s are Designed and Built for Maximum Acceptance on Each Operating Cycle

In the smaller residential Well-X-Trol®s, the design is for basic intermittent use and for the usually found in residential applications. Standard pressure ranges of (20) PSIG (between pump cut-in and pump cut-out) are used.

In these applications, full use of the maximum acceptance volume of the Well-X-Trol®is rarely required to meet job conditions.

Tab le 1.

WX Model No.

WX Model

Total

Maximum

Maximum

NON-CODE

No.

Volume

Acceptance

Acceptance

(NON-AS ME )

COD E

(Gallons)

Volume

Factor

 

(ASM E)

 

(Gallons)

(MAF)

WX-401

WX-401-C

17.5

11.25

.65

WX–402

WX–402-C

25

11.25

.45

WX-403

WX-403-C

34

11.25

.33

WX-404

WX-404-C

68

34

.50

WX-405

WX-405-C

90

34

.39

WX-406

WX-406-C

110

34

.31

WX-407

WX-407-C

132

46

.35

WX-421

Not available

158

103

.65

WX-422

Not available

211

137

.65

WX-423

Not available

264

172

.65

WX-424

Not available

317

206

.65

WX-426

Not available

422

274

.65

WX-427

Not available

528

343

.65

WX-447

WX-447-C

53

34

.65

WX-448

WX-448-C

80

52

.65

WX-449

WX-449-C

106

69

.65

WX-450

WX-450-C

132

86

.65

WX-451

WX-451-C

158

102

.65

WX-452

WX-452-C

211

136

.65

WX-453

WX-453-C

264

170

.65

WX-454

WX-454-C

317

205

.65

WX-455

WX-455-C

370

239

.65

WX-456

WX-456-C

422

273

.65

WX-457

WX-457-C

528

341

.65

Based on 30 PS IG p re-charge (P1)