Configuring Communication

5.Click on the Virtual NetLinx Master radio box from the Transport Connection Option section to indicate wanting to configure the PC to communicate with a panel. Everything else, such as the Authentication, is greyed out because the procedure is not being made through the Master’s UI.

6.Click the Edit Settings button in the Communications Settings dialog to open the Virtual NetLinx Master Settings dialog (FIG. 42).

IP Addresses of computer (also obtained by using the

Start > Run > cmd command)

FIG. 42 Virtual NetLinx Master Settings dialog box

7.From within this dialog, enter the System number (default is 1) and note the IP Address of the target PC being used as the Virtual Master. This IP Address can also be obtained by following these procedures:

On the PC, click Start > Run to open the Run dialog.

Enter cmd into the Open field and click OK to open the command DOS prompt.

From the C:\> command line, enter ipconfig to display the IP Address of the PC. This information is entered into the Master IP/URL field on the panel.

8.Click OK to close the open dialogs, save the settings, and return to the main NetLinx Studio application.

9.Click the OnLine Tree tab in the Workspace window to view the devices on the Virtual System. The default System value is one.

10.Right-click on the Empty Device Tree/System entry and select Refresh System to re-populate the list.

11.Place the panel in the Table Charging Station or in the Wall Charging Station and turn the panel On.

12.After the panel powers up, press and hold down the navigation wheel center button for 3 seconds to continue with the setup process and proceed to the Setup page.

MVP-5200i Modero Viewpoint Widescreen Touch Panel

39

 

 

Page 47
Image 47
AMX MVP-5200i manual Start Run cmd command