12English
6.3 Oil Change
Caution - Danger!
Spent oil must not be dumped because it is a pollutant. It must be disposed of in accordance with legal requirements.
Change pump and reduction gearbox oil (where fitted) after first 50 hours of operation, and every 500 hours thereafter.
Remove the casing (where fitted) to change the oil. Replace the casing (where fitted) when done.
6.3.1Changing the pump oil
Unscrew the drain plug and allow all the spent oil to flow out.
Screw the plug back into place. Pour in oil through the filler hole. Check that the oil level is correct.
For oil characteristics, refer to the“Oil characteris- tics” table.
6.3.2Changing the reduction gearbox oil (where fitted) Unscrew the drain plug and allow all the spent oil to flow out.
Screw the plug back into place. Pour in oil through the filler hole. Check that the oil level is correct.
For oil characteristics, refer to the “Oil character- istics” table.
Table 1 - Oil characteristics
Component | Oil type | Quantity (kg) | |
|
|
| |
Pump 850 | SAE 30 W | 0.9 | |
|
|
| |
Pump 840 | SAE 30 W | 0.9 | |
|
|
| |
Pump 830 | SAE 30 W | 0.3 | |
|
|
| |
Pump 820 | SAE 30 W | 0.3 | |
|
|
| |
Pump 810 | SAE 75 W90 | 0.135 | |
|
|
| |
Reduction | AGIP BLASIA W90 | 0.21 | |
gearbox | |||
|
| ||
|
|
|
6.4Storage
Treat the appliance with
7TROUBLESHOOTING
Problem | Possible causes | Remedy | |
|
|
| |
| Nozzle worn | Replace nozzle | |
| Water filter fouled | Clean filter (fig.5) | |
| Water supply pressure low | Turn on water supply tap fully | |
Pump does not reach work- | Air being sucked into system | Check tightness of hose fittings | |
ing pressure |
| Switch off the cleaner and keep depressing and | |
| Air in pump | releasing the gun trigger until the water comes out | |
|
| in a steady flow. Switch the cleaner back on again. | |
| Adjustable nozzle not positioned correctly | Turn the adjustable nozzle “E” (+) (fig.3) | |
| Water intake from external tank | Connect cleaner to the mains water supply | |
Pressure drops during use | Intake water too hot | Reduce temperature | |
| Nozzle clogged | Clean nozzle (fig.5) | |
Water leakage | Seals worn | Have the seals replaced at your nearest Authorised | |
Service Centre | |||
|
| ||
Cleaner noisy | Water too hot | Reduce temperature (see technical data | |
Oil leakage | Seals worn | Contact your nearest Authorised Service Centre | |
Engine malfunction |
| Refer to the engine manufacturer’s manual. | |
Water escapes from ther- | Water temperature inside nozzle has exceeded | With appliance in operation, do not stop the water | |
mostat valve | max. rated value stated on nameplate | jet for more than 5 minutes at a time |