Specifications | SPECIFICATIONS | |
| ||
#75003 Pool Pilot Digital Control unit | ||
Input Power |
|
|
230 Vac | 1.5 amps | (Normal input configuration shipped from the factory) |
115 Vac | 3 amps | (Optional input configuration – jumper wire to convert included) |
Dry Contact | 5 mA typical | |
Chlorine Output |
| |
SuperCell Type | Maximum Chlorine Output (# 75003 Control unit set on Cell Power 3) | |
| 1.28 lbs/day (0.58 kg/day) | |
| 1.56 lbs/day (0.71 kg/day) | |
| 1.92 lbs/day (0.88 kg/day) | |
| 2.50 lbs/day (1.14 kg/day) – Commercial Cell |
Manifold Flow Requirements
Minimum Flow Rate | 20 gallons per minute (gpm) (76 liters/minute (L/m)) |
Maximum Flow Rate | 100 gallons per minute (gpm) (379 liters/minute (L/m)) |
Maximum Pressure | 85 psi (as tested by NSF) |
Pump/Auxiliary Relay Output
Voltage Input | Amps / HP max |
115 Vac | 30 amps / 1 HP |
230 Vac | 30 amps / 2.5 HP |
Agency Approvals
•ETL tested to conform to the following UL specifications:
oUL1081 - Standard for Safety for Swimming Pool Pumps, Filters and Chlorinators
oUL 1563 - Standard for Safety for Electric Spas, Equipment Assemblies, and Associated Equipment.
•
#75001 Pool Pilot Pool Chemistry Control unit
pH Acid Feed Pump and Tank AC Input Power
#75004 | 120 Vac | 1.7 amps |
#75005 | 220 Vac | 0.9 amps |
#75006 | 230 Vac | 0.9 amps |
#75007 | 250 Vac | 0.9 amps |
#75008 Auxiliary Relay Kit | 115 / 230 Vac Relay | 30 amps max |
Low Voltage Input Power
PCC Communication | Factory Low Voltage Interface Cable provided with #75001 |
#75008 pH Auxiliary Relay Kit | (Optional) Dedicated Factory Low Voltage Terminal |
Flow Cell
Flow Sensor | Fail – Safe status |
Maximum working pressure | 50 psi |
4