24
Winterizing Procedure Continued:
Location of External Drain Plug will vary by model
MAINTENANCE
& OPERATION (continued)
1. Disconnect all electrical power to the heater; turn OFF circulating pump.
2. At the two (2) connection unions, disconnect the plumbing to the heater (removal is counter-
clockwise).
3. If your unit has an external drain plug, remove plug. This plug would be located at lower, front
corner of heater. (position may vary between models). Allow water to drain out of the condensor.
DO NOT replace plug until final winterizing step.
5. Replace the winterizing plug; thread the plug in clockwise until just snug, thenapply an additional
1/8 turn. To prevent insects and vermin from entering the plumbing during the winterized period,
partially reconnect the two (2) plumbing connection unions: couple each union one or two
threads; this will permit condensation to drain, but will prevent most insects and animals from
entering the plumbing circuit.
6.. Next Season: To ready the heat pump for use, simply retighten plumbing connection unions.
Hand-tight is generally sufficient.
4. If no external drain plug is found, it will be necessary to open access panel and see if heat
exchanger has an internal drain plug. If so, remove plug, and allow water to drain out of the
condensor.
Location of
Internal Drain
Plug
No internal drain
plug with this
heat exchanger.
Water Heat Exchangers
PLEASE NOTE - If your heat pump contains an exchanger other than what is shown above,
call AquaCal AutoPilot for alternate winterizing instructions.