51
Controls Configuration & Adjustments...
Microprocessor Factory Default Settings
Level –1 and Level-2 Default Settings
Microprocessor Level-2 Set Up & Calibration Codes
Service Adjustable Parameters
Code Description Factory Setting Range
[LOC] Servic e L ock Code 50 00-99
[dEL] 4-minut e Delay on Make 1 0 / 1
[JAO] External Contro ller Int erf ace 0 0 / 2 / 3
[FS2] Flow Switch / Auto T-Stat Switching 0 0 / 1
[tSC] W ater Sensor Calibrat ion Factory Calibrated +10o to –10o of display
[dSC] Defrost Sensor Calibrat io n Factory Calibrated +10o to –10o of display
[dBS] Spa Dead Band Differential 1o 1
o to 5o
[dBP] Pool Dead Band Differential 1o 1
o to 5o
Menu Code Description Default Value Range
Level-1 [CF1] Celsius/Fahrenheit 1 0 / 1
Level-1 [ULC] User Lock Code 0 0 / 1
Level-1 [ELC] Enter Lock Code 0 00-99
Level-1 [CFO] Call / Flex 0 0 / 1 / 2
Level-1 [LOC] Service Lock Code 50 00-99
Mode Key Pad Operating Mode OFF
For Heat Only: OFF/HEAT
For Hea t & Cool:
OFF, HEA , CO O , A CH
Thermostat Key Pad Thermostat Settings Pool & Spa OFF 45oF – 104oF
Level-2 [dEL]
Anti-Short Cycle, 4-mi nute Delay
on Make 1 0 / 1
Level-2 [JAO] External Controller Interface 0 0 / 2 / 3
Level-2 [FS2] Flow Switch / Automatic
Thermostat Switching 0 0 / 1
Level-2 [tSC] Water Sensor Calibration Factory Calibrated +10o to –10o of displayed
value
Level-2 [dSC] Defrost Sensor Calibration Factory Calibrated +10o to –10o of displayed
value
Level-2 [dBS] Spa Dead Band Differential 1o 1
o to 5o
Level-2 [dBP] Pool Dead Band Differential 1o 1
o to 5o