Power ON Detection
The Power On Detection feature enables the switch to use the next active port automatically when the active port is unplugged.
When the switch is turned on, the first plug in port acts as the active port.
Note: The switch does not use the next active port if the current port is not the active port and two active ports are turned on.
RS-232 Serial Interface
The VS481A’s
Configuring the Serial Port
The controller’s serial port should be configured as follows:
Baud Rate | 19200 |
|
|
Data Bits | 8 |
|
|
Parity | None |
|
|
Stop Bits | 1 |
|
|
Flow Control | None |
|
|
Switch Port Commands
The formulas for Switch Port commands are as follows:
1.Switch Command + Input Port number + Output Port number [Enter]
For example, to switch input port 02 to output port 01, input the following:
sw i02 o01 [Enter]
2. Switch Command + Port Sequence [Enter]
- 14 -