Avaya ALGO-3226-CM manual Verification Steps, Conclusion, Additional References, in-service/idle

Models: ALGO-3226-CM

1 8
Download 8 pages 22.56 Kb
Page 7
Image 7

7. Verification Steps

The following steps can be used to verify and/or troubleshoot installations in the field.

1.Verify that the staus of the loop start trunk connected to the 3226 Trunk Port FXO Doorphone is in-serviceusing the status trunk command on Communication Manager. Below is the output of the command.

status

trunk 100

 

 

 

 

 

TRUNK GROUP STATUS

 

 

 

 

 

Member

 

Port

Service State

Mtce Connected Ports

 

 

 

 

Busy

0100/001

001V208

in-service/idle

no

 

 

 

 

 

2.Verify that when the call button on the Door Station is pressed, the specified telephone on Communication Manager rings, and upon answering the call, two-way audio path is established.

3.Verify that the 3226 Trunk Port FXO Doorphone returns to the idle state when the call is terminated.

4.Verify that incoming calls to the 3226 Trunk Port FXO Doorphone are also successful.

8. Conclusion

These Application Notes describe the administration steps required to integrate the Algo 3226 Trunk Port FXO Doorphone with Avaya Aura® Communication Manager. Calls to the 3226 Trunk Port FXO Doorphone were successful in both directions. In addition, unlocking a door using DTMF tones was successful. All test cases passed.

9. Additional References

This section references documentation relevant to these Application Notes. The following Avaya product documentation is available at http://support.avaya.com.

[1]Administering Avaya AuraTM Communication Manager, June 2010, Release 6.0, Issue 6.0, Document Number 03-300509.

The following Algo product documentation is available at http://www.algosolutions.com.

[2]Algo 3226 Trunk Port FXO Doorphone Installation and User Guide, Document Number 90- 00040A.

JAO; Reviewed:

Solution & Interoperability Test Lab Application Notes

7 of 8

SPOC 11/3/2011

©2011 Avaya Inc. All Rights Reserved.

Algo-3226-CM

Page 7
Image 7
Avaya ALGO-3226-CM manual Verification Steps, Conclusion, Additional References, in-service/idle