Chapter 2 Hardware Installation

C. COIL RATINGS (at 20 oC )

 

Coil Nominal Voltage

Coil Resistance

Pick-up Voltage

Drop-Out Voltage

Nominal Current

 

(VDC)

10%

(VDC)

(VDC)

 

(mA)

 

5

125

3.75

0.5

 

40

* Max Continuous Voltage at 20oC : 110% of Coil Nominal Voltage

 

 

 

D. CONTACT RATINGS

 

 

 

 

 

 

 

 

 

 

 

 

Contact Arrangement

 

 

1 Form C (SPDT)

 

max. Switch Power

 

 

125VA

60W

 

max. Switch voltage

 

 

125VAC

30VDC

 

max. Switch current

 

 

 

1A

 

Contact Resistance

 

 

≤ 100mΩ

 

Resistive Load

 

 

1A/125VAC

 

 

 

1A/30VDC

 

 

 

 

 

2.14 Connecting POS (Point of Sales)

AVerMedia® AVerDVR can be integrated with POS system equipment. Connecting the POS equipment to AVerMedia® AVerDVR system thru RS232 connection, enables you to view, record and keep track of the items that were sold. You may also select the camera on where to display all the data.

To connect, locate the RS232 port of the POS equipment and PC. Use an RS232 cable (not supplied) to make the connection.

RS232 cable

i

For detail of POS installation, please refer to POS Quick Guide.

25