10. Service menus
10.3 Identification screen
What can be seen on the identification screen?
The identification screen shows the general information of the projector.
The following items will be displayed:
Typeof projector: CineVERSUM 70
IR address = address used for the remote control
RSa ddress = address used with RS232/422 serial communication
Software version
Baudrate: transferspeed for communication through RS232/RS422 with an external device or computer. The baud rate of the
projectormust be the same asthe baud rate of the connected computer or external device.
ProjectorSerial number: indicatesthe fabrication number of the projector. This number can be useful when calling for technical
assistance.
LampRun Time: givesthe total run time since the first start up of this lamp.
Manufacturing date
How to display the identificationwindow ?
1. Push the cursor key or to highlight Identification. (menu 10-3)
2. Press ENTER to select.
The Identification window appears. (menu 10-4)
Service
Identification
Password
IR address : 000
RS232 address : 000
Serial communication
Thermal diagnosis
I2C diagnosis
Back
Menu10-3
Identification
CineVERSUM 70
IR address : 000
RS address : 000
Soft. version : 07A00F22Z
Baudrate PC : 19200
Serial number : 6002316
Lamp runtime : 28h
Manuf. Date : Apr. 14 2004
Back
Menu10-4
10.4 Password
Overview
Enable-disable password
Modify password
10.4.1 Enable-disable password
Why password ?
Witha password itis possible to protect all settings in Advanced Settings,Installation and Service.
When the password isenabled, onlyperson who knows the password can get in.
72 R5976763 CINEVERSUM 60/70 22042004