EN 10
6.1.4Custom Arming
Custom arming is used to arm zones that you specify and your installer programs into your system. An entry/exit delay is in effect unless otherwise programmed.
The green Status LED must be lit and, if using a text keypad, “Ready to Arm” must be displayed. If the green LED is not on or the keypad displays “Not Ready,” you must use other methods to arm the system (refer to Section 6.2.2 Force Arming on page 13 or Section 6.2.3 Zone Bypass on page 14).
Table 6: Custom Arming
|
|
|
|
Equipment | Command Sequence | What Happens | What To Do |
|
|
|
|
Text Keypad LED | [PIN][#][4] | • The red Armed LED flashes. | Exit during the |
Keypad |
| • “On Partial” is displayed. * | period. |
|
| • “Exit Now” is displayed during the exit- |
|
|
| delay period. * |
|
|
| • The green Status LED lights steady. |
|
|
| • A single beep sounds. |
|
|
| • The red Armed LED lights steady when |
|
|
| the |
|
|
| • The zones that were programmed for |
|
|
| custom arming are armed. |
|
RF3341 Keypad | [PIN][#][4] | • The LED flashes indicating a signal was | Exit during the |
|
| sent to your security system. | period. |
|
| • The zones programmed for custom |
|
|
| arming are armed. |
|
RF3332/RF3332E, |
| Not applicable |
|
RF3334/RF3334E |
|
|
|
* Text Keypad only |
|
|
|
Bosch Security Systems 6/05 4998154961B