6 720 607 072
20
Appliance details
When the heater is in operation you will hear i ts power
vent fan and burner operating. Upon turning off the hot
water flow the power vent fan will continue to operate
for up to 60 seconds to exhaust all flue gases. The
power vents fan speed is variable depending on the rate
of hot water used and the burner output.
TO TURN OFF GAS TO APPLIANCE
BTurn off the manual gas shut off on the supply line to
the heater and set the ON/OFF switch to the OFF (0)
position. Note: a manual ga s shut off valve is not
supplied with the heater.
i
NOTE: on a first time initial instal-
lation or after gas line work has
been done, existence of air in the
gas line will cause ignition delay
when the hot water is turned on.
This will result in an error (EA) on
the units display screen. This is
normal. When this occurs, leave
the hot water running and wait 3-5
seconds, then reset the unit (Fig.
26, pos. 2). Wait for (EA) to disap-
pear. The heater will begin to at-
tempt ignition again, if the (EA)
reappears then repeat this same
process until all air has been bled
from the gas line.