6 720 608 124
Appliance details
3
2 Appliance details
2.1 GWH 1000 P specifications
(Technical data)
Approved in US/Canada
Capacity
GWH 1000 P: 2.6 GPM
Maximum output
GWH 1000 P: 58 400 Btu/hr
Maximum input
GWH 1000 P: 74 900 Btu/hr
Efficiency in %
Recovery efficiency 78%
Min. Output
GWH 1000 P: 23 906 Btu/hr
Gas Requirement
Gas connection (inches) - ½” NPT
Inlet gas pressure under maximum operation*
Propane: 10.5” - 14” water column
Natural Gas: 5.7” - 14” water column.
* To measure Gas Pressure, see Measuring Gas
Pressure, chapter 3.8.
Venting
Natural Draft
Vent diameter (inches) - 4”
Minimum height (feet) - 6’ with no elbows
Vertical termination.
Water
Hot water connection (inches) - ½” NPT
Cold water connection (inches) - ½” NPT
Water valve material: Polymer (PPS) (Polypropyle ne
Sulfid)
Minimum water flow: 0.5 gallon/minute (1.9 l/m)
Minimum recommended water pressure: 13 PSI
(0.9bar)
• Connections:
Bottom of heater
Dimensions
Depth (in): 8.66” (220 mm)
Width (in): 12.20” (310 mm)
Height (in): 22.83” (580 mm)
Weight: 26 pounds (12 kg).
Gas types
Natural Gas
LP Gas
Safety devices
Flame failure device (ionization thermocouple)
Pressure relief valve (supplied with heater)
Over heat prevention (temperature limiter).
Water resistant
IP X4.