Image 38

38 en Configuration

DINION 5000 AN

 

 

5.6.4Alarm I/O submenu

Item

Selection

Description

 

 

 

Input

None, high,

Select none to disable the alarm input.

 

low

Select active-high or active-low for the

 

 

alarm input connector.

 

 

 

Input action

None,

Selects the operating mode of the

 

Mode 1 to 6,

camera when the alarm input is active.

 

Night mode

 

 

 

 

Output

Normally

Selects the relay output mode.

 

open,

 

 

Normally

 

 

closed

 

 

 

 

Output action

VMD,

VMD: - output relay closes on VMD

 

Ext. device,

alarms.

 

Night mode,

External device: - make the output

 

Filter toggle

relay available to remote

 

 

communication devices.

 

 

Night mode: - output relay closes when

 

 

camera is in monochrome mode.

 

 

Filter toggle: - output relay closes just

 

 

before the IR filter starts moving and

 

 

opens when video level has stabilized

 

 

(2 to 3 seconds)

 

 

 