5.6.5Connections submenu

Item

Selection

Description

 

 

 

Bilinx Comms.

On, Off

If Off, Bilinx communications is

 

 

disabled.

 

 

 

Camera

Enable,

Enable or disable the camera buttons

buttons

disable

from working.

 

 

 

Cable

Off, Default,

Cable compensation is used to avoid

compensation

RG59, RG6

the need for amplifiers in long distance

 

 

coaxial connections up to 1000 m

 

 

(3000 ft). For optimum results select

 

 

the coaxial cable type used or, if

 

 

unknown, select default.

 

 

 

Compensation

0,1,2 . . .+15

Sets the level of cable compensation

level

 

 

 

 

 

EXIT

 

Returns to Install menu.

 

 

 

5.6.6Test signal submenu

Item

Selection

Description

 

 

 

Show camera

Off, On

Select On to overlay the camera ID on

ID

 

the video test signal.

 

 

 

Test pattern

Color bars,

Select the desired test pattern to help

 

Raster,

installation and fault-finding.

 

Impulse,

 

 

Cross

 

 

Impulse,

 

 

Crosshatch

 

 

 

 

EXIT

 

Returns to Install menu.

 

 

 