Specifications
Thermal well TCO Limit Residential 188°F (87°C), Commercial 199°F (93°C)
Residential Temperature
Set Point Range 60°F (16°C) to 160°F (71°C) (Approximate temperatures)
Blower Temperature
Switch Normally closed, opens @ 165°F (74°C), auto reset @ 130°F (54°C).
Blower 115VAC, 60Hz, 3.1 amps.
Pressure switch
Exhaust-Normally open, closes on vacuum increase @ -1.30.
Intake-Normally closed, opens on v acuum increase @ -1.15.
Power supply Dedicated 115VAC, 60 Hz, 15A
Approved Gas Type Natural or Propane. Unit must match gas type supplied.
Venting System Power vent through t he wall or vertical through the roof
Approved Vent Materials PVC, CPVC or ABS
Gas Supply Pipe Minimum 1/2" NPT (schedule40 black iron pip e recommended)
Minimum Clearance
for Servicing 18" from top, 24" from front, 4" sides and rear.
Water Supply Pressure 15 0 PSI maximum allowable working pressure. Check local codes for supply pressure
Gas Pressure 5.0"W.C. min. for Nat gas, 11.0" W.C. min. for L. P. gas, 14.0" W.C. maximum (Nat. & L.P.)
Commercial Temperature
Set Point Range 80°F (27°C) to 180°F (82°C) (Approximate temperatures)
Page 6
PDX Series
6