3.Measure the resistance between the trigger coil (A, Figure 54) and ground.
1.Locate the connector for the ignition coil (A, Figure 56) and disconnect..
AA
Figure 54
Figure 56
•If
•If resistance is not to specifications, check wire
| connections and retest. | 2. Attach meter test leads to primary side of the ignition |
• | If resisitance is still not to specifications, replace | coil and measure the resistance (B, Figure 57). |
| coil. |
|
If resistance is still not to specifications, proceed to Step 3. |
| |
4. Disconnect ignition charge coil connection (B, Figure 55) |
| |
and measure the resistance between the connector and |
| |
ground. |
|
| B | Not |
|
|
| B | |
|
| for | |
|
| Figure 57 | |
|
|
| |
|
|
| • If resistance is 0.8 - 1.3 Ω the primary coil is good. |
|
|
| Reproduction |
|
|
| • If resistance is not to specifications, check wire |
|
|
| connections, or repair/replace wires then retest. |
Figure 55 |
|
| • If resistance is still not to specification, replace the |
|
|
| coil. |
•If
•If resistance is not to specifications, check wire connections and retest.
•If resisitance is still not to specification, replace coil.