MODEL C500

MODEL C501CY

MODEL C501K

READ AND SAVE THESE INSTRUCTIONS

INSTALLATION

ALL ELECTRICAL WORK MUST BE DONE IN ACCORDANCE WITH LOCAL AND/ OR NATIONAL ELECTRICAL CODE AS APPLICABLE.

TURN OFF POWER AT SERVICE ENTRANCE BEFORE INSTALLING, WIRING, OR SERVICING THIS PRODUCT.

1.Hold chime mechanism against wall and mark four (4) mounting holes.

2.Drill 3/16” holes where marked and tap in wall anchors from parts bag.

3.Bring wiring through access hole(s) in chime mechanism backplate.

4.Attach chime mechanism to wall with screws from parts bag. Tighten screws securely.

5.Hang chime tubes from mechanism as shown.

DO NOT OIL CHIME PLUNGERS.

Oil will cause them to stick during operation. If plungers fail to operate freely due to accumulation of dust, cooking grease, etc., clean with a non-flammable cleaning solvent which will evaporate, leaving a dry surface.