11. ELECTRICAL MECHANISM

 

 

 

 

 

 

 

 

 

 

 

 

Cause

Inspection/Remedy/Adjustment

Replacement if a malfunction

 

 

 

 

 

 

 

5. When [Err 91] is displayed:

Repeat the standard settings for the treadle

-

 

 

Problem with treadle unit settings

unit. (Refer to “12-3. Standard settings for

 

 

 

 

 

 

 

 

treadle depression stroke”.)

 

 

 

 

 

 

 

 

6. When [Err 450] is displayed:

(Replace the part(s) indicated at right.)

Machine head memory unit

 

 

Problem with machine head

 

 

 

 

memory data; Model selection

 

 

 

 

cannot be loaded

 

 

 

 

7. When [Err 452] is displayed:

Check that connector P6 (HEAD-M) is inserted

Machine head memory unit

 

 

Machine head memory cannot be

into the main P.C. board.

 

 

 

verified.

 

 

 

 

 

 

 

 

 

8. When [Err 403] is displayed:

1) Check that connector P31 (PMD) is inserted

Harness, PMD P.C. board,

 

 

Poor connection between main

into the main P.C. board and that connector

main P.C. board

 

 

P.C. board and PMD P.C. board

P1 (MAIN) is inserted into the PMD P.C.

 

 

 

 

board.

 

 

 

 

 

 

 

 

 

2) Check if there is a harness short-circuit.

Harness

 

 

 

 

 

 

 

9. When [Err 401] or [Err 411] is

Turn the power switch off and back on again.

Main P.C. board

 

 

displayed:

 

 

 

 

Main P.C. board communication

 

 

 

 

error

 

 

 

 

10. When [Err 700] is displayed:

Check that the power supply voltage at the wall

-

 

 

Abnormal rise in power supply

outlet is within the range of the specification

 

 

 

voltage

voltage +/- 10%.

 

 

 

 

 

 

 

 

11. When [Err 705] is displayed:

Check that the power supply voltage at the wall

-

 

 

Abnormal drop in power supply

outlet is within the range of the specification

 

 

 

voltage

voltage +/- 10%.

 

 

 

 

 

 

 

 

12. When [Err 101] is displayed:

Set DIP switch No. 4 to OFF and then turn the

-

 

 

DIP switch No. 4 on the main P.C.

power switch off and back on.

 

 

 

board is ON

 

 

 

 

 

 

 

 

 

 

 

 

13. When [Err 200] is displayed:

Check that connector P5 (PMD) is inserted into

Needle zigzag motor or PMD

 

 

Needle zigzag motor is not

the PMD P.C. board.

P.C. board

 

 

connected

 

 

 

 

 

 

 

 

 

14. When [Err 131] is displayed:

Check that connector P13 (ENC) is inserted

Sewing machine motor or main

 

 

Encoder cord of sewing machine

into the main P.C. board.

P.C. board

 

 

motor is not connected.

 

 

 

 

 

 

 

 

Problem No. 3 “UP” is displayed when the power switch is turned on.

Cause

 

Inspection/Remedy/Adjustment

Replacement if a malfunction

 

 

 

 

Malfunction of encoder P.C. board in

1)

Turn the pulley to move the needle bar to

Encoder P.C. board in sewing

sewing machine motor

 

the needle up stop position.

machine motor

 

 

 

 

 

2)

Check if the needle up signal remains on.

 

 

 

 

 

Z-8550A, 8560A

98