| 11. ELECTRICAL MECHANISM |
|
|
|
|
|
|
|
|
|
|
|
| Cause | Inspection/Remedy/Adjustment | Replacement if a malfunction |
|
|
|
|
|
|
| 5. When [Err 91] is displayed: | Repeat the standard settings for the treadle | - |
|
| Problem with treadle unit settings | unit. (Refer to |
|
|
|
|
|
| |
|
| treadle depression stroke”.) |
|
|
|
|
|
|
|
| 6. When [Err 450] is displayed: | (Replace the part(s) indicated at right.) | Machine head memory unit |
|
| Problem with machine head |
|
|
|
| memory data; Model selection |
|
|
|
| cannot be loaded |
|
|
|
| 7. When [Err 452] is displayed: | Check that connector P6 | Machine head memory unit |
|
| Machine head memory cannot be | into the main P.C. board. |
|
|
| verified. |
|
|
|
|
|
|
|
|
| 8. When [Err 403] is displayed: | 1) Check that connector P31 (PMD) is inserted | Harness, PMD P.C. board, |
|
| Poor connection between main | into the main P.C. board and that connector | main P.C. board |
|
| P.C. board and PMD P.C. board | P1 (MAIN) is inserted into the PMD P.C. |
|
|
|
| board. |
|
|
|
|
|
|
|
|
| 2) Check if there is a harness | Harness |
|
|
|
|
|
|
| 9. When [Err 401] or [Err 411] is | Turn the power switch off and back on again. | Main P.C. board |
|
| displayed: |
|
|
|
| Main P.C. board communication |
|
|
|
| error |
|
|
|
| 10. When [Err 700] is displayed: | Check that the power supply voltage at the wall | - |
|
| Abnormal rise in power supply | outlet is within the range of the specification |
|
|
| voltage | voltage +/- 10%. |
|
|
|
|
|
|
|
| 11. When [Err 705] is displayed: | Check that the power supply voltage at the wall | - |
|
| Abnormal drop in power supply | outlet is within the range of the specification |
|
|
| voltage | voltage +/- 10%. |
|
|
|
|
|
|
|
| 12. When [Err 101] is displayed: | Set DIP switch No. 4 to OFF and then turn the | - |
|
| DIP switch No. 4 on the main P.C. | power switch off and back on. |
|
|
| board is ON |
|
| |
|
|
|
| |
|
|
|
|
|
| 13. When [Err 200] is displayed: | Check that connector P5 (PMD) is inserted into | Needle zigzag motor or PMD |
|
| Needle zigzag motor is not | the PMD P.C. board. | P.C. board |
|
| connected |
|
|
|
|
|
|
|
|
| 14. When [Err 131] is displayed: | Check that connector P13 (ENC) is inserted | Sewing machine motor or main |
|
| Encoder cord of sewing machine | into the main P.C. board. | P.C. board |
|
| motor is not connected. |
|
|
|
|
|
|
|
|
Problem No. 3 “UP” is displayed when the power switch is turned on.
Cause |
| Inspection/Remedy/Adjustment | Replacement if a malfunction |
|
|
|
|
Malfunction of encoder P.C. board in | 1) | Turn the pulley to move the needle bar to | Encoder P.C. board in sewing |
sewing machine motor |
| the needle up stop position. | machine motor |
|
|
|
|
| 2) | Check if the needle up signal remains on. |
|
|
|
|
|
98 |