Page 34
SERVICE (cont.)
SOLENOID VALVE (Inlet) (cont.)
P799
VIO to Level Control Board T1 (Electro/mechanical)
WHI/BLU to Control Assy #1 (Electronic)
WHI to Level Control Board T3
(120/208V or 120/240V Electro/mechanical)
WHI to Terminal Block (120/208V or 120/240V
Electronic)
Red to Level Control Board T3 (200 or 240V
Electro/mechanical or Control Assy T4 Electronic)
P984
START SWITCHES
Location:
The momentary start switches are located in
front of hood just left and right of center.
Test Procedure:
1. Disconnect the brewer from the power source and
remove the wires from both terminals of the switch.
2. Check for continuity across the two terminals
on the switch when it is held in the lower position.
Continuity must not be present across these ter-
minals in the upper position.
If continuity is present as described, reconnect the
wires, the switch is operating properly.
If continuity is not present as described, replace the
switch.
Removal and Replacement:
1. Remove all wires from the switch terminals.
2. Compress the clips inside the hood and gently
push the switch through the opening.
3. Push the new switch into the opening and spread
the clips to hold the switch in the hood.
4. Refer to the following illustration when reconnect-
ing the wires.
P992
solenoid valve.
10. Refer to the illustration below when reconnecting
the wires.
BUNN
MANUFACTURED BY BUNN-O-MATIC CORPORATION
SPRINGFIELD, ILLINOIS, U.S.A.
MODELS/N
VOLTS A.C. AMP WATTS
PHASE WIRE HERTZ
COVERED UNDER ONE OR MOREOF THE FOLLOWING PATENTS :
ONE OR MORE OTHER PATENTS MAY BE PENDING
OPERATING PROCEDURES
1.Check Server size if
Brewer refuses to brew.
2.McDonald's Brew
Temperature: 200°F ± 5°
(3-18-96)
CAUTION
DISCARD DECANTER
IF:
. CRACKED
. SCRATCHED
. BOILED DRY
. HEATED WHEN EMPTY
. USED ON HIGH FLAME
. OR EXPOSED ELECTRIC
ELEMENTS
FAILURE TO COMPLY RISKS INJURY
PN: 6581985 BUNN-O-MATIC CORPORATION
FUNNEL CONTENTS
ARE HOT
!
C
A
U
T
I
O
N
!
H
O
T
L
I
Q
U
I
D
C
A
U
T
I
O
N
!
H
O
T
L
I
Q
U
I
D
!
CAUTIONHOT WATER
DISCONNECT FROM POWER SOURCE
BEFORE REMOVAL OF ANY PANEL OR
REPLACEMENT OF ANY COMPONENT!
WARNING
!
RIGHT
LEFT
GRN to Left Relay Terminal "A"
WHI/RED to Left ON/OFF Switch
to Left Timer TL1
WHI/VIO to Right ON/OFF Switch
and Right Timer TL1
GRN to Right Relay Terminal "A"
27124 050800