Page 30
SERVICE (cont.)
START/STOP SWITCHES
Location:
The momentary START/STOP switches are lo-
cated in front of hood just left and right of center.
Test Procedure:
1. Disconnect the brewer from the power source.
P2235
CAUTION
DISCARD DECANTER
DISCARD DECANTER
IF:
IF:
. CRACKED
. CRACKED
. SCRATCHED
. SCRATCHED
. BOILED DRY
. BOILED DRY
. HEATED WHEN EMPTY
. HEATED WHEN EMPTY
. USED ON HIGH FLAME
. USED ON HIGH FLAME
. OR EXPOSED ELECTRIC
. OR EXPOSED ELECTRIC
ELEMENTS
ELEMENTS
FAILURE TO COMPLY RISKS INJURY
FAILURE TO COMPLY RISKS INJURY
PN: 658
PN: 658
1985 BUNN-O-MATIC CORPORATION
1985 BUNN-O-MATIC CORPORATION
FUNNEL CONTENTS
FUNNEL CONTENTS
ARE HOT
ARE HOT
!
DISCONNECT FROM POWER SOURCE
BEFORE REMOVAL OF ANY PANEL OR
REPLACEMENT OF ANY COMPONENT!
WARNING
!
FIG. 31 START/STOP SWITCHES
P2214
FIG. 32 START/STOP SWITCH TERMINALS
#2 BLK to Signal Harness
32248 100500
RIGHT LEFT
#3 BLK to SH Transformer #1
#4 RED to Signal Harness
#5 BLK to Over Limit
#6 ORN to Interface Circuit Board
#3 BLK to SH Transformer #1
#4 BLU to Signal Harness
#5 BLK to Over Limit
#6 YEL to Interface Circuit Board
#2 BLK to Signal Harness
Removal and Replacement:
1. Remove all wires from the switch terminals.
2. Compress the clips inside the hood and gently
push the switch through the opening.
3. Push the new switch into the opening and spread
the clips to hold the switch in the hood.
4. Refer to Fig. 32 when reconnecting the wires.
#1 Not Used