4 OPERATION
4.4 Mains Protections
4.4.1 Inrush Current Limitation
Within approximately 2 seconds of the
4.4.2 Mains Over Voltage Detection
Mains Over Voltage Detection is always operative. When the mains voltage exceeds approx. 263 V (230 V operation) or 137 V (120 V operation), the amplifier will switch off. When the mains voltage returns to nominal value a soft start occurs.
4.4.3 Mains Failure Detection
Mains Failure Detection is always operative.When the mains supply is interrupted for about 2 mains cycles, the amplifier will switch off.When the mains voltage returns to a normal value a soft start occurs.
4.4.4 Fuse Protection
The fuse protection circuit prevents amplifier
In order to prevent any shutdown in extreme situations the amplitude of the input signals will be reduced which will in return also reduce the mains current draw.
4.5Main SMPS Protections 4.5.1 Over Current Protection
The main SMPS (Switched Mode Power Supply) transformer current of your
4.5.2 Thermal Protection
If the temperature of the main SMPS transformer exceeds 90 °C, the main SMPS is switched off (safety
4.6 Fans
The fans mounted in your