Operation Guide 3147
Current Stopwatch Session Record
The current stopwatch session record contains the data described below. The contents of this record are retained until you start a new Altimeter Mode stopwatch measurement session.
Data | Description |
High Altitude | Highest altitude reached during the current Altimeter Mode |
(MAX) | stopwatch session. |
Low Altitude | Lowest altitude reached during the current Altimeter Mode |
(MIN) | stopwatch session. |
Total Ascent | Total cumulative ascent during the current Altimeter Mode |
(ASC) | stopwatch session. |
Total Descent | Total cumulative descent during the current Altimeter |
(DSC) | Mode stopwatch session. |
•The maximum total ascent and total descent value is 99,995 meters
(or 99,980 feet). Each value reverts to zero after the maximum is reached.
How current Altimeter Mode stopwatch session record data is updated Note
•When you press E to start a new Altimeter Mode stopwatch session, the watch will clear data that is already stored in the current stopwatch session record.
•The watch takes altitude readings and calculates data as described below, and updates the current stopwatch session record accordingly. Note that measurement and saves depend on whether or not the watch is in the Altimeter Mode.
•In the Altimeter Mode
Altitude Measurement | First 3 minutes | After 3 minutes |
Interval |
|
|
0'05" | Updated every 5 | Updated every 5 seconds |
seconds |
| |
|
| |
2'00" | Updated every 5 | Updated every 2 minutes |
seconds |
| |
|
|
•Outside the Altimeter Mode
Readings are taken and session data is updated every two minutes.
Historical Record
The historical record keeps track of high altitude, low altitude, total ascent, and total descent values across multiple Altimeter Mode stopwatch sessions. The contents of this record are updated continually while an Altimeter Mode stopwatch operation is in progress.
How the historical record is updated
The watch performs the following operations continually while an Altimeter Mode stopwatch operation is in progress.
Data | Update Operation |
High Altitude | The historical record value is compared with the current |
| reading and the greater of the two is recorded in the |
| historical record. |
Low Altitude | The historical record value is compared with the current |
| reading, and the lesser of the two is recorded in the |
| historical record. |
|
|
Total Ascent | The current Altimeter Mode stopwatch session value is |
Total Descent | added to the historical record value. |
|
|
•See “Clearing the Historical Record” for information about clearing the historical record, which restarts all data values from zero.
Other Altimeter Mode Features
This section explains other features and settings that are available in the Altimeter Mode. Note that all of the information in this section applies to all types of Altimeter Mode measurements, unless specifically indicated otherwise.
Specifying a Reference Altitude
After you specify a reference altitude, the watch adjusts its
To specify a reference altitude
|
|
|
|
| 1. In the Altimeter Mode, hold down A for about |
|
|
|
|
| two seconds until either OFF or the current |
|
| lllllll |
| reference altitude value starts to flash. This is | |
|
|
| the setting screen. | ||
| l | l |
| ||
l |
|
| l |
| |
ll |
|
|
| l | 2. Press E (+) or B |
l |
|
| l |
| |
l |
|
| l | reference altitude value by 5 meters (or 20 feet). | |
| l | ll | |||
|
| llllll |
|
|
• You can specify the reference altitude within the range of
• Pressing E and B at the same time returns to OFF (no reference altitude), so the watch performs air pressure to altitude conversions based on preset data only.
3. Press A to exit the setting screen.
Altitude graph
|
|
|
|
|
| The altitude graph shows Altimeter Mode |
|
|
|
|
|
| |
|
|
|
|
| Altitude | measurement results. |
|
|
|
|
| ||
|
|
|
|
| • The vertical axis of the graph represents | |
|
|
|
|
|
| |
|
|
|
|
|
| altitude, and each dot stands for 10 meters (40 |
Time |
|
| feet). | |||
|
|
|
•The horizontal axis represents time, and the flashing dot in the rightmost column indicates the latest measurement result. For the first three minutes, each dot represents five seconds. After that, each dot represents two minutes.
•An out of range measurement result or a measurement error will cause the column of dots for that measurement to be blank (skipped).
Recalling Altitude Data
Use the Data Recall Mode to view altitude records currently in memory, as well as the current Altimeter Mode stopwatch session record, and the historical record. Altitude records are created and stored by the watch in the Altimeter Mode.
Data Screens
The following explains the contents of each of the screens that appear in the Data Recall Mode.
Note
•While an altitude record screen, or the high altitude or low altitude screen is displayed, the bottom part of the display alternates between the measurement date (month and day) and measurement time, at
|
| Measurement time |
| Alternates at | (Hour : Minutes) |
Record | ||
▲ |
| |
name | ▲ |
Altitude
Measurement date (Month – Day)
Altitude Records
These are records of the 20 newest altitude readings taken with the watch by you. If you take more than 20 readings, the watch will delete the oldest readings to make room for the newest readings.
Current Stopwatch Session Record
The following data items are included in the current stopwatch session record.
Data Type | Screen Name | Description |
High Altitude | MAX | Highest altitude reached during the last |
|
| Altimeter Mode stopwatch session. |
Low Altitude | MIN | Lowest altitude reached during the last |
|
| Altimeter Mode session. |
Total Ascent | ASC | Total cumulative ascent during the last |
|
| Altimeter Mode session. |
Total Descent | DSC | Total cumulative descent during the last |
|
| Altimeter Mode session. |
Historical Record
The historical record contains data for all Altimeter Mode stopwatch sessions performed since the last time the historical record was cleared.
Data Type | Screen Name | Description |
High Altitude | MAX | Highest altitude reached during all |
|
| Altimeter Mode stopwatch sessions. |
Low Altitude | MIN | Lowest altitude reached during all |
|
| Altimeter Mode stopwatch sessions. |
Total Ascent | ASC | Total cumulative ascent during all Altimeter |
|
| Mode stopwatch sessions. |
Total Descent | DSC | Total cumulative descent during all |
|
| Altimeter Mode stopwatch sessions. |
5