Operation Guide 3147

Current Stopwatch Session Record

The current stopwatch session record contains the data described below. The contents of this record are retained until you start a new Altimeter Mode stopwatch measurement session.

Data

Description

High Altitude

Highest altitude reached during the current Altimeter Mode

(MAX)

stopwatch session.

Low Altitude

Lowest altitude reached during the current Altimeter Mode

(MIN)

stopwatch session.

Total Ascent

Total cumulative ascent during the current Altimeter Mode

(ASC)

stopwatch session.

Total Descent

Total cumulative descent during the current Altimeter

(DSC)

Mode stopwatch session.

The maximum total ascent and total descent value is 99,995 meters

(or 99,980 feet). Each value reverts to zero after the maximum is reached.

How current Altimeter Mode stopwatch session record data is updated Note

When you press E to start a new Altimeter Mode stopwatch session, the watch will clear data that is already stored in the current stopwatch session record.

The watch takes altitude readings and calculates data as described below, and updates the current stopwatch session record accordingly. Note that measurement and saves depend on whether or not the watch is in the Altimeter Mode.

In the Altimeter Mode

Altitude Measurement

First 3 minutes

After 3 minutes

Interval

 

 

0'05"

Updated every 5

Updated every 5 seconds

seconds

 

 

 

2'00"

Updated every 5

Updated every 2 minutes

seconds

 

 

 

Outside the Altimeter Mode

Readings are taken and session data is updated every two minutes.

Historical Record

The historical record keeps track of high altitude, low altitude, total ascent, and total descent values across multiple Altimeter Mode stopwatch sessions. The contents of this record are updated continually while an Altimeter Mode stopwatch operation is in progress.

How the historical record is updated

The watch performs the following operations continually while an Altimeter Mode stopwatch operation is in progress.

Data

Update Operation

High Altitude

The historical record value is compared with the current

 

reading and the greater of the two is recorded in the

 

historical record.

Low Altitude

The historical record value is compared with the current

 

reading, and the lesser of the two is recorded in the

 

historical record.

 

 

Total Ascent

The current Altimeter Mode stopwatch session value is

Total Descent

added to the historical record value.

 

 

See “Clearing the Historical Record” for information about clearing the historical record, which restarts all data values from zero.

Other Altimeter Mode Features

This section explains other features and settings that are available in the Altimeter Mode. Note that all of the information in this section applies to all types of Altimeter Mode measurements, unless specifically indicated otherwise.

Specifying a Reference Altitude

After you specify a reference altitude, the watch adjusts its air-pressure-to- altitude conversion calculation accordingly. The altitude measurements produced by this watch are subject to error caused by changes in air pressure. Because of this, we recommend that you update the reference altitude whenever one is available during your climb.

To specify a reference altitude

 

 

 

 

 

1. In the Altimeter Mode, hold down A for about

 

 

 

 

 

two seconds until either OFF or the current

 

 

lllllll

 

reference altitude value starts to flash. This is

 

 

 

the setting screen.

 

l

l

 

l

 

 

l

 

ll

 

 

 

l

2. Press E (+) or B (–) to change the current

l

 

 

l

 

l

 

 

l

reference altitude value by 5 meters (or 20 feet).

 

l

ll

 

 

llllll

 

 

You can specify the reference altitude within the range of –10,000 to 10,000 meters (–32,800 to 32,800 feet).

Pressing E and B at the same time returns to OFF (no reference altitude), so the watch performs air pressure to altitude conversions based on preset data only.

3. Press A to exit the setting screen.

Altitude graph

 

 

 

 

 

 

The altitude graph shows Altimeter Mode

 

 

 

 

 

 

 

 

 

 

 

Altitude

measurement results.

 

 

 

 

 

 

 

 

 

 

The vertical axis of the graph represents

 

 

 

 

 

 

 

 

 

 

 

 

altitude, and each dot stands for 10 meters (40

Time

 

 

feet).

 

 

 

The horizontal axis represents time, and the flashing dot in the rightmost column indicates the latest measurement result. For the first three minutes, each dot represents five seconds. After that, each dot represents two minutes.

An out of range measurement result or a measurement error will cause the column of dots for that measurement to be blank (skipped).

Recalling Altitude Data

Use the Data Recall Mode to view altitude records currently in memory, as well as the current Altimeter Mode stopwatch session record, and the historical record. Altitude records are created and stored by the watch in the Altimeter Mode.

Data Screens

The following explains the contents of each of the screens that appear in the Data Recall Mode.

Note

While an altitude record screen, or the high altitude or low altitude screen is displayed, the bottom part of the display alternates between the measurement date (month and day) and measurement time, at 1-second intervals.

 

 

Measurement time

 

Alternates at

(Hour : Minutes)

Record

1-second intervals.

 

name

Altitude

Measurement date (Month – Day)

Altitude Records

These are records of the 20 newest altitude readings taken with the watch by you. If you take more than 20 readings, the watch will delete the oldest readings to make room for the newest readings.

Current Stopwatch Session Record

The following data items are included in the current stopwatch session record.

Data Type

Screen Name

Description

High Altitude

MAX

Highest altitude reached during the last

 

 

Altimeter Mode stopwatch session.

Low Altitude

MIN

Lowest altitude reached during the last

 

 

Altimeter Mode session.

Total Ascent

ASC

Total cumulative ascent during the last

 

 

Altimeter Mode session.

Total Descent

DSC

Total cumulative descent during the last

 

 

Altimeter Mode session.

Historical Record

The historical record contains data for all Altimeter Mode stopwatch sessions performed since the last time the historical record was cleared.

Data Type

Screen Name

Description

High Altitude

MAX

Highest altitude reached during all

 

 

Altimeter Mode stopwatch sessions.

Low Altitude

MIN

Lowest altitude reached during all

 

 

Altimeter Mode stopwatch sessions.

Total Ascent

ASC

Total cumulative ascent during all Altimeter

 

 

Mode stopwatch sessions.

Total Descent

DSC

Total cumulative descent during all

 

 

Altimeter Mode stopwatch sessions.

5