Operation Guide 3148

Charging Precautions

Certain charging conditions can cause the watch to become very hot. Avoid leaving the watch in the areas described below whenever charging its rechargeable battery.

Also note that allowing the watch to become very hot can cause its liquid crystal display to black out. The appearance of the LCD should become normal again when the watch returns to a lower temperature.

Warning!

Leaving the watch in bright light to charge its rechargeable battery can cause it to become quite hot. Take care when handling the watch to avoid burn injury. The watch can become particularly hot when exposed to the following conditions for long periods.

On the dashboard of a car parked in direct sunlight

Too close to an incandescent lamp

Under direct sunlight

Charging Guide

After a full charge, timekeeping remains enabled for up to about five months.

The following table shows the amount of time the watch needs to be exposed to light each day in order to generate enough power for normal daily operations.

Exposure Level (Brightness)

Approximate

 

Exposure Time

Outdoor Sunlight (50,000 lux)

5 minutes

Sunlight Through a Window (10,000 lux)

24 minutes

Daylight Through a Window on a Cloudy Day (5,000 lux)

48 minutes

Indoor Fluorescent Lighting (500 lux)

8 hours

Since these are the specs, we can include all the technical details.

Watch not exposed to light

Internal timekeeping

Display on 18 hours per day, sleep state 6 hours per day

1 illumination operation (1.5 seconds) per day

10 seconds of alarm operation per day

1 hour of altimeter measurement at 5-second interval, once per month

2 hours of barometric pressure measurement per day

Stable operation is promoted by frequent exposure to light.

Recovery Times

The table below shows the amount exposure that is required to take the battery from one level to the next.

Exposure Level

Approximate Exposure Time

 

 

(Brightness)

Level 5

Level 4

Level 3

Level 2

Level 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outdoor Sunlight

 

1 hour

14 hours

4 hours

(50,000 lux)

 

 

 

 

 

 

 

 

 

 

 

 

 

Sunlight Through a

 

4 hours

69 hours

19 hours

Window (10,000 lux)

 

 

 

 

 

 

 

 

 

 

 

 

 

Daylight Through a

 

6 hours

139 hours

38 hours

Window on a Cloudy

 

 

 

 

 

 

 

 

Day (5,000 lux)

 

 

 

 

 

 

 

 

 

 

 

 

 

Indoor Fluorescent

 

62 hours

- - - - - - - -

- - - - - - - -

Lighting (500 lux)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The above exposure time values are all for reference only. Actual required exposure times depend on lighting conditions.

Reference

This section contains more detailed and technical information about watch operation. It also contains important precautions and notes about the various features and functions of this watch.

Auto Return Features

The watch returns to the Timekeeping Mode automatically if you do not perform any button operation for two or three minutes in the Data Recall, Alarm, or Barometer/Thermometer Mode.

If you do not perform any button operation for 21 or 22 hours while in the Altimeter Mode, the watch will return to the Timekeeping Mode automatically.

If you leave a screen with flashing digits on the display for two or three minutes without performing any operation, the watch exits the setting screen automatically.

Initial Screens

When you enter the World Time or Alarm Mode, the data you were viewing when you last exited the mode appears first.

Scrolling

The E and B buttons are used on the setting screen to scroll through data on the display. In most cases, holding down these buttons during a scroll operation scrolls through the data at high speed.

Sensor Malfunction Indicator

Subjecting the watch to strong impact can cause sensor malfunction or improper contact of internal circuitry. When this happens, ERR (error) will appear on the display and sensor operations will be disabled.

Barometric Pressure

Altitude

Measurement

Measurement

If ERR appears while a measurement operation is being performed in a sensor mode, restart the measurement. If ERR appears on the display again, it can mean there is something wrong with the sensor.

Even if battery power is at Level 1 or Level 2, the Barometer/Thermometer Mode or Altimeter Mode sensor may be disabled if there is not enough voltage available to power it sufficiently. In this case, ERR will appear on the display. This does not indicate malfunction, and sensor operation should resume once battery voltage returns to its normal level.

If ERR keeps appearing during measurement, it could mean there is a problem with the applicable sensor.

Whenever you have a sensor malfunction, be sure to take the watch to your original dealer or nearest authorized CASIO distributor as soon as possible.

Button Operation Tone

The button operation tone sounds any time you press one of the watch’s buttons. You can turn the button operation tone on or off as desired.

Even if you turn off the button operation tone, the alarm, Hourly Time Signal, and Countdown Timer Mode alarm all operate normally.

To turn the button operation tone on and off

In any mode (except when a setting screen is on Mute indicator the display), hold down D to toggle the button

operation tone on (MUTE not displayed) and off (MUTE displayed).

Since the D button is also the mode change button, holding it down to turn the button operation on or off also causes the watch’s current mode to change.

The MUTE indicator is displayed in all modes when the button operation tone is turned off.

Power Saving

When turned on, Power Saving enters a sleep state automatically whenever the watch is left for a certain period in an area where it is dark. The table below shows how watch functions are affected by Power Saving.

There actually are two sleep state levels: “display sleep” and “function sleep”.

Elapsed Time in

Display

Operation

Dark

 

 

60 to 70 minutes

Blank, with

Display is off, but all functions

(Display Sleep)

PS flashing

are enabled.

6 or 7 days

Blank, with

All functions are disabled, but

(Function Sleep)

PS not flashing

timekeeping is maintained.

Wearing the watch inside the sleeve of clothing can cause it to enter the sleep state.

The watch will not enter the sleep state while the digital time is between 6:00 AM and 9:59 PM. If the watch is already in the sleep state when the digital time reaches 6:00 AM, however, it will remain in the sleep state.

The watch will not enter the sleep state while it is in the Barometer/ Thermometer, Altimeter, Countdown Timer, or Stopwatch Mode. When the watch is left in any mode besides the Countdown Timer and Stopwatch Mode, the watch will return to the Timekeeping Mode automatically after a specific amount of time. Then if left in the dark for the elapsed time indicated in the table above, the watch will enter the sleep state.

To recover from the sleep state

Perform any one of the following operations.

Move the watch to a well-lit area. It can take up to two seconds for the display to turn on.

Press any button.

Angle the watch towards your face for reading.