To use the cash register’s basic function

ƒƒ Daily read/reset report

Mode Switch

At the end of the business day, you can print categorized and sum-

 

marized results of the day. Reset report (Z) clears all the sales data

 

whereas the data remains in memory by Read report (X).

 

Please do not perform the Reset report (Z) printing while your store is open. It clears all the sales data.

Step

1 Turn the Mode switch to X or Z and press p. The printer prints Read (X) or Reset

(Z) report.

Operation

p

Printout

01−21−2013

19:25

Z

CLERK01

0073

0000 DAILY

Z 0012

DEPT01

QT

48

 

 

$50.10

DEPT02

QT

28

 

 

$76.40

DEPT03

QT

17

 

 

$85.80

DEPT20

QT

4

 

 

$3.00

•••••••••••••••••••••••

GROSS TOTAL

QT

108

 

 

$316.80

NET TOTAL

No

46

 

 

$325.13

CASH−INDW

 

$199.91

CHARGE−INDW

 

$16.22

CHECK−INDW

 

$105.00

TA1

 

$105.10

TAX1

 

$4.20

ROUNDING AMT

 

$1.23

RF−MODE TTL

No

2

 

 

$0.50

CALCULATOR

No

3

Date/Time

Consecutive No.

Z Report Symbol/Non resettable consecutive No.

Dept. Name/ No. of Items

Amount

Gross Sales No. of Items

Gross Sales Amount

Net Sales No. of Customers

Net Sales Amount

Cash in Drawer

Charge in Drawer

Check in Drawer

Taxable Amount for Tax Rate 1

Tax Amount for Tax Rate 1

Rounded Amount

RF Mode Count

RF Mode Amount

E-26